Produkte > FLUKE > Alle Produkte des Herstellers FLUKE (5191) > Seite 80 nach 87

Wählen Sie Seite:    << Vorherige Seite ]  1 8 16 24 32 40 48 56 64 72 75 76 77 78 79 80 81 82 83 84 85 87  Nächste Seite >> ]
Foto Bezeichnung Hersteller Beschreibung Verfügbarkeit
Preis
ohne MwSt
FLUKE 772
+10
FLUKE 772 FLUKE FLK-770-DTE.PDF Fluke 772 Datasheet (EN).pdf Fluke 772 Datasheet (DE).pdf Fluke 772 Manual (EN).pdf Fluke 772 Manual (DE).pdf Category: Clamp Meters - Others
Description: Meter: current loop; pincers type; LCD; IP40; Illumin: yes
Type of meter: current loop
Kind of meter: pincers type
Measurement: 4-20mA current loop
Measuring instrument features: 0-24mA direct current source and simulation mode; automatic power-off; direct current loop 24 V supply option; HOLD function
Dimensions: 246x70x44mm
Power supply: battery LR6 AA 1,5V x4
Operating temperature: -10...50°C
Kind of display used: LCD
Signal measurements: 0-20,99mA (0,01mA resolution, accuracy: 0,2% + 5 digits); 21-100mA (0,1mA resolution, accuracy: 1% + 5 digits)
Alias: 3362352
Illumination: yes
Additional functions: torch
IP rating: IP40
Produkt ist nicht verfügbar
FLUKE 773
+11
FLUKE 773 FLUKE FLK-770-DTE.PDF Category: Clamp Meters - Others
Description: Meter: current loop; pincers type; LCD; VDC: 0÷30V; IP40
Type of meter: current loop
Kind of display used: LCD
DC voltage measuring range: 0...30V
Measurement: 4-20mA current loop; DC voltage
Measuring instrument features: 0-24mA direct current source and simulation mode; automatic power-off; direct current loop 24 V supply option; HOLD function; scaled output signal mA; simultaneous measurement of current intensity (mA) and source mode (mA); type of 0-10 V source of direct current
IP rating: IP40
Operating temperature: -10...50°C
Power supply: battery LR6 AA 1,5V x4
Dimensions: 246x70x44mm
Kind of meter: pincers type
Illumination: yes
Additional functions: torch
Signal measurements: 0-20,99mA (0,01mA resolution, accuracy: 0,2% + 5 digits); 21-100mA (0,1mA resolution, accuracy: 1% + 5 digits)
auf Bestellung 7 Stücke:
Lieferzeit 14-21 Tag (e)
1+2028.31 EUR
FLUKE-1773 FLUKE flk-210548-en-1770-series-ds-w.pdf?_QKpV7UdY52BPvb.mUS9MzVGDY74jSlr Category: Power Quality Analyzers
Description: Meter: power quality logger; Network: three-phase; 280x190x62mm
Type of meter: power quality logger
Kind of network: three-phase
Measurement: AC current; active electric energy; active power; AC voltage; apparent electric energy; apparent power; DC current; DC voltage; frequency; harmonics; inrush current; reactive electric energy; reactive power
Interface: Bluetooth (option); Ethernet; USB; WiFi (option)
Manufacturer series: FLK-1770
Power supply: rechargeable battery Li-Ion x1
Measuring instrument features: built- in report generator; memory built-in; transfer measurement data wireless
Standard equipment: adapter for main socket FLK-174X-MA-C8; cable markers; crocodile clip, black FLK-AC285 x4; crocodile clip, green FLK-AC285; FLK-i17XX-FLEX1500 - current clamp x4; manufacturer's calibration certificate; test lead; test lead 3-phase + N; test leads set FLK-17XX 0,18M
IP rating: IP50
Operating temperature: -10...50°C
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Dimensions: 280x190x62mm
Weight with battery: 2.1kg
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Software: Fluke Energy Analyze Plus
Produkt ist nicht verfügbar
FLUKE-1775
+1
FLUKE-1775 FLUKE flk-210548-en-1770-series-ds-w.pdf?_QKpV7UdY52BPvb.mUS9MzVGDY74jSlr Category: Power Quality Analyzers
Description: Meter: power quality logger; Network: three-phase; 280x190x62mm
Type of meter: power quality logger
Kind of network: three-phase
Measurement: AC current; active electric energy; active power; AC voltage; apparent electric energy; apparent power; DC current; DC voltage; frequency; harmonics; inrush current; reactive electric energy; reactive power; transients
Interface: Bluetooth; Ethernet; USB; WiFi
Manufacturer series: FLK-1770
Power supply: rechargeable battery Li-Ion x1
Measuring instrument features: built- in report generator; memory built-in; transfer measurement data wireless
Standard equipment: adapter for main socket FLK-174X-MA-C8; cable markers; case; crocodile clip, black FLK-AC285 x4; crocodile clip, green FLK-AC285; FLK-i17XX-FLEX1500 - current clamp x4; magnetic hanging strap; manufacturer's calibration certificate; MP1 magnet probe (3 red and 1 black); test lead; test lead 3-phase + N; test leads set FLK-17XX 0,18M; WiFi and Bluetooth module
IP rating: IP50
Operating temperature: -10...50°C
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Dimensions: 280x190x62mm
Weight with battery: 2.1kg
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Software: Fluke Energy Analyze Plus
Produkt ist nicht verfügbar
FLUKE-1777
+4
FLUKE-1777 FLUKE flk-210548-en-1770-series-ds-w.pdf?_QKpV7UdY52BPvb.mUS9MzVGDY74jSlr Category: Power Quality Analyzers
Description: Meter: power quality logger; Network: three-phase; 280x190x62mm
Type of meter: power quality logger
Kind of network: three-phase
Measurement: AC current; active electric energy; active power; AC voltage; apparent electric energy; apparent power; DC current; DC voltage; frequency; harmonics; inrush current; reactive electric energy; reactive power; transients
Interface: Bluetooth; Ethernet; USB; WiFi
Manufacturer series: FLK-1770
Power supply: rechargeable battery Li-Ion x1
Measuring instrument features: built- in report generator; memory built-in; transfer measurement data wireless
Standard equipment: adapter for main socket FLK-174X-MA-C8; cable markers; crocodile clip, black FLK-AC285 x4; crocodile clip, green FLK-AC285; FLK-i17XX-FLEX1500 - current clamp x4; hard case; magnetic hanging strap; manufacturer's calibration certificate; MP1 magnet probe (3 red and 1 black); test lead; test lead 3-phase + N; test leads set FLK-17XX 0,18M; WiFi and Bluetooth module
IP rating: IP50
Operating temperature: -10...50°C
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Dimensions: 280x190x62mm
Weight with battery: 2.1kg
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Software: Fluke Energy Analyze Plus
Produkt ist nicht verfügbar
FLUKE 1577
+4
FLUKE 1577 FLUKE 10923-eng.pdf 15x7____umeng0200.pdf 15x7____umger0200.pdf Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Illumination: yes
Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test
Type of meter: digital multimeter
Weight with battery: 550g
Optional equipment: FLK-C25 soft cover
Continuity test: acoustic indication; <25Ω
True effective value measurement: True RMS AC
Measurement: AC current; AC voltage; DC current; DC voltage; insulation resistance; resistance
Dimensions (W x H x D): 100x203x50mm
Test voltage: 500V; 1kV
AC current measuring range: 10µA...60mA; 400mA
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 10µA...60mA; 400mA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ
Display parameters: (6000)
AC current measuring accuracy: ±(2% + 2 digit)
DC voltage measuring accuracy: ±(0.2% + 2 digit)
DC current measuring accuracy: ±(1% + 2 digit)
AC voltage measuring accuracy: ±(2% + 3 digit)
Resistance measuring accuracy: ±(1.2%+2 digit)
Insulation resistance measuring accuracy: ±(2% + 5digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x4
IP rating: IP40
Produkt ist nicht verfügbar
FLUKE 377 FC
+5
FLUKE 377 FC FLUKE FLK-377FC_378FC_EN.pdf Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Interface: Bluetooth
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x2
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Software: Fluke Connect
True effective value measurement: True RMS
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; inrush current; resistance
Kind of meter: digital; pincers type
AC current measuring range: 100mA...999.9A
Resistance measuring range: 600Ω; 6kΩ; 60kΩ
DC current measuring range: 100mA...999.9A
DC voltage measuring range: 600V; 1kV
AC voltage measuring range: 600V; 1kV
Frequency measuring range: 5...500Hz
Capacitance measuring range: 0.1...100µF; 1mF
CF crest factor: 1.42 @ 1kA; 2.5 @ 600A; 3 @ 500A
Frequency measuring accuracy: ±(0.5%+5 digit)
Capacitance measuring accuracy: ±(1%+ 4 digit)
AC current measuring accuracy: ±(2% + 5 digit)
DC voltage measuring accuracy: ±(1% + 5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
AC voltage measuring accuracy: ±(1.5% + 5 digit)
Resistance measuring accuracy: ±(1%+5 digit)
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Illumination: yes
Dimensions: 274x86x47mm
Standard equipment: case; crocodile clip FLK-AC285; FLK-I2500-18 flexible current probe; magnetic hanging strap FLK-TOOLPAK; test leads FLK-TL-224; test probes TP175
Measuring instrument features: automatic power-off; contactless voltage measurement; flexible current probe up to 2500A; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; transfer measurement data wireless
Type of meter: multifunction
Weight with battery: 463g
Test: diodes
Continuity test: acoustic indication; <30Ω
Pollution degree: 2
Max. diameter of measured cable: 34mm
auf Bestellung 8 Stücke:
Lieferzeit 14-21 Tag (e)
1+880.38 EUR
FLUKE-1773/BASIC FLUKE Category: Power Quality Analyzers
Description: Meter: power quality logger; Network: three-phase; 280x190x62mm
Dimensions: 280x190x62mm
Interface: Bluetooth (option); Ethernet; USB; WiFi (option)
Manufacturer series: FLK-1770
Operating temperature: -10...50°C
Standard equipment: adapter for main socket FLK-174X-MA-C8; cable markers; crocodile clip, black FLK-AC285 x4; crocodile clip, green FLK-AC285; manufacturer's calibration certificate; test lead; test lead 3-phase + N; test leads set FLK-17XX 0,18M
Measuring instrument features: built- in report generator; memory built-in; transfer measurement data wireless
Type of meter: power quality logger
Weight with battery: 2.1kg
Measurement: AC current; active electric energy; active power; AC voltage; apparent electric energy; apparent power; DC current; DC voltage; frequency; harmonics; inrush current; reactive electric energy; reactive power
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Software: Fluke Energy Analyze Plus
Power supply: rechargeable battery Li-Ion x1
IP rating: IP50
Kind of network: three-phase
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Produkt ist nicht verfügbar
FLUKE-1775/BASIC
+1
FLUKE-1775/BASIC FLUKE Category: Power Quality Analyzers
Description: Meter: power quality logger; Network: three-phase; 280x190x62mm
Dimensions: 280x190x62mm
Interface: Bluetooth; Ethernet; USB; WiFi
Manufacturer series: FLK-1770
Operating temperature: -10...50°C
Standard equipment: adapter for main socket FLK-174X-MA-C8; cable markers; case; crocodile clip, black FLK-AC285 x4; crocodile clip, green FLK-AC285; manufacturer's calibration certificate; test lead; test lead 3-phase + N; test leads set FLK-17XX 0,18M
Measuring instrument features: built- in report generator; memory built-in; transfer measurement data wireless
Type of meter: power quality logger
Weight with battery: 2.1kg
Measurement: AC current; active electric energy; active power; AC voltage; apparent electric energy; apparent power; DC current; DC voltage; frequency; harmonics; inrush current; reactive electric energy; reactive power; transients
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Software: Fluke Energy Analyze Plus
Power supply: rechargeable battery Li-Ion x1
IP rating: IP50
Kind of network: three-phase
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Produkt ist nicht verfügbar
FLUKE-1777/BASIC
+4
FLUKE-1777/BASIC FLUKE Category: Power Quality Analyzers
Description: Meter: power quality logger; Network: three-phase; 280x190x62mm
Dimensions: 280x190x62mm
Interface: Bluetooth; Ethernet; USB; WiFi
Manufacturer series: FLK-1770
Operating temperature: -10...50°C
Standard equipment: adapter for main socket FLK-174X-MA-C8; cable markers; crocodile clip, black FLK-AC285 x4; crocodile clip, green FLK-AC285; hard case; manufacturer's calibration certificate; test lead; test lead 3-phase + N; test leads set FLK-17XX 0,18M
Measuring instrument features: built- in report generator; memory built-in; transfer measurement data wireless
Type of meter: power quality logger
Weight with battery: 2.1kg
Measurement: AC current; active electric energy; active power; AC voltage; apparent electric energy; apparent power; DC current; DC voltage; frequency; harmonics; inrush current; reactive electric energy; reactive power; transients
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Software: Fluke Energy Analyze Plus
Power supply: rechargeable battery Li-Ion x1
IP rating: IP50
Kind of network: three-phase
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Produkt ist nicht verfügbar
77-4/EUR
+4
77-4/EUR FLUKE FLK-77-IV.pdf 77iv____umeng0000.pdf 77iv____umger0000.pdf Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.32x/s
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Continuity test: acoustic indication; <25Ω
Bargraph: 33 segm. 32x/s
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Dimensions (W x H x D): 90x185x43mm
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 1mV...6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1mA @2.4V
Battery/ rechargeable battery: battery 6LR61 9V x1
Display parameters: (6000)
Frequency measuring accuracy: ±(0.1%+1 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
AC current measuring accuracy: ±(2% + 2 digit)
DC voltage measuring accuracy: ±(0.3% + 1 digit)
DC current measuring accuracy: ±(1.5% + 2 digit)
AC voltage measuring accuracy: ±(2% + 2 digit)
Resistance measuring accuracy: ±(0.5%+1 digit)
Kind of display used: LCD
Power supply: battery 6LR61 9V x1
Standard equipment: test leads; user's manual
Measuring instrument features: auto and manual ranging; automatic power-off; HOLD function; MIN/MAX/MEDIUM function
Type of meter: digital multimeter
auf Bestellung 3 Stücke:
Lieferzeit 14-21 Tag (e)
1+817.86 EUR
2824477
+1
2824477 FLUKE Category: Accessories - Others
Description: Battery container
Related items: FLK-289
Type of test accessories: battery container
auf Bestellung 3 Stücke:
Lieferzeit 14-21 Tag (e)
1+109.14 EUR
3114277 FLUKE Category: Accessories for Oscilloscopes - Others
Description: Rechargeable battery; FLK-1760
Type of test accessories: rechargeable battery
Related items: FLK-1760
Produkt ist nicht verfügbar
Fluke C101 Fluke C101 FLUKE Category: Bags & Soft Cases
Description: Hard carrying case; FLK-1503,FLK-1507,FLK-1577,FLK-1587
Type of test accessories: hard carrying case
Related items: FLK-1503; FLK-1507; FLK-1577; FLK-1587
Dimensions: 305x360x105mm
Produkt ist nicht verfügbar
FLUKE 1560856 FLUKE 1560856 FLUKE Category: Accessories - Others
Description: Display; FLK-177EGFID
Related items: FLK-177EGFID
Type of test accessories: display
auf Bestellung 4 Stücke:
Lieferzeit 14-21 Tag (e)
3+29.99 EUR
Mindestbestellmenge: 3
FLUKE 3000FC/EDA2
+5
FLUKE 3000FC/EDA2 FLUKE Category: Portable digital multimeters
Description: Digital multimeter; POM-5677B,POM-5899A,POM-7519A
Type of meter: digital multimeter
Standard equipment: FLK-3000FC wireless multimeter; FLK-C35 soft cover; manual (CD); test leads FLK-TL-224; test probes FLK-AC280 SureGrip; test probes FLK-TL910
Related items: POM-5677B; POM-5899A; POM-7519A
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)
1+708.18 EUR
FLUKE 179/EDA2/EUR
+9
FLUKE 179/EDA2/EUR FLUKE Fluke 175 177 179 Datasheet EN.pdf 175_____umeng0100.pdf Fluke 175 177 179 Manual EN.pdf 175_____umger0100.pdf Fluke 175 177 179 Manual DE.pdf Category: Portable digital multimeters
Description: Digital multimeter; POM-5904A/POM,POM-6343,POM-7519A
Related items: POM-5904A/POM; POM-6343; POM-7519A
Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type temperature probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; set of test leads with probes FLK-TL910; test leads FLK-TL224 SureGrip; test probes FLK-AC280 SureGrip
Battery/ rechargeable battery: battery 6LR61 9V x1
Type of meter: digital multimeter
auf Bestellung 12 Stücke:
Lieferzeit 14-21 Tag (e)
1+687.63 EUR
FLUKE 179 MAG KIT
+8
FLUKE 179 MAG KIT FLUKE 175_____umeng0100.pdf 175_____umger0100.pdf Category: Portable digital multimeters
Description: Digital multimeter; POM-5904A/POM,POM-6343,POM-7519A
Related items: POM-5904A/POM; POM-6343; POM-7519A
Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type temperature probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; mini torch; test leads FLK-TL224 SureGrip; test probes FLK-AC220 SureGrip; test probes FLK-TP4
Battery/ rechargeable battery: battery 6F22 9V x1
Type of meter: digital multimeter
auf Bestellung 35 Stücke:
Lieferzeit 14-21 Tag (e)
1+595.61 EUR
FLUKE 179EGFID/C11XT FLUKE 179EGFID/C11XT FLUKE Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Power supply: battery 6LR61 9V x1
Battery/ rechargeable battery: battery 6LR61 9V x1
Manufacturer series: Fluke 170
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5904A/POM; POM-6343; POM-7519A
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
Frequency measuring accuracy: ±(0,1% + 1 digits)
Resistance measuring accuracy: ±(0,9% + 1 digit)
Standard equipment: FLK-80BK-A drop-like K-type temperature probe; FLK-TL75 test leads
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; EVA-C11XT hard case; FLK-C90 soft cover; FLK-TLK220 set
DC current measuring accuracy: ±(1% + 3 digits)
Kind of display used: LCD
Temperature measuring range: -40...400°C
Continuity test: acoustic indication; <25Ω
True effective value measurement: True RMS AC
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Weight with battery: 420g
Diode test: 1.1mA @2.4V
DC voltage measuring accuracy: ±(0,09% + 2 digits)
Bargraph: 33 segm. 40x/s
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC current measuring accuracy: ±(1,5% + 3 digits)
Temperature measurement accuracy: ±(1% + 10 digits)
Alias: 5575193
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Dimensions (W x H x D): 89x190x45mm
Type of meter: digital multimeter
AC voltage measuring accuracy: ±(1% + 3 digits)
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Display parameters: 3,75 digit (6000)
Capacitance measuring accuracy: ±(1,2% + 2 digits)
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)
1+648.72 EUR
FLUKE-9040EUR
+1
FLUKE-9040EUR FLUKE 11078-eng.pdf Category: Phase Sequence Indicators
Description: Tester: phase sequence; LCD; Freq: 15÷400Hz; IP40
Operating frequency: 15...400Hz
Type of tester: phase sequence
Related items: FLK-BP291; FLK-C25; FLK-TLK290; FLK-TLK291
Standard equipment: 3 crocodile clips; test leads ( 3pcs.)
Weight with battery: 200g
Pollution degree: 2
Phase-to-phase voltage range for phase sequence indication: 40...700V AC
IP rating: IP40
Power supply: from tested wiring system
Measurement: motor's rotation direction; phase sequence
Kind of display used: LCD
Body dimensions: 124x61x27mm
Conform to the norm: CAT III 600V; CAT IV 300V; EN 61010
auf Bestellung 11 Stücke:
Lieferzeit 14-21 Tag (e)
1+358.62 EUR
FLUKE 9062 FLUKE 9062 FLUKE 11078-eng.pdf 9062____umeng0000.pdf 9062____umger0000.pdf Category: Phase Sequence Indicators
Description: Tester: phase sequence; LED; 120÷400VAC; Freq: 2÷400Hz; IP40
Operating frequency: 2...400Hz
Type of tester: phase sequence
Related items: FLK-C25; FLK-TLK290; FLK-TLK291
Standard equipment: 3 crocodile clips; test leads ( 3pcs.)
Measuring instrument features: non-contact determination of rotation field direction; voltage indicator individual for each phase
Weight with battery: 150g
Pollution degree: 2
Phase-to-phase voltage range for phase sequence indication: 120...400V AC; 1...400V AC
IP rating: IP40
Power supply: battery 6LR61 9V x1
Measurement: motor's rotation direction; phase sequence
Kind of display used: LED
Body dimensions: 124x61x27mm
Battery/ rechargeable battery: battery 6LR61 9V x1
Conform to the norm: CAT III 300V; EN 61010
auf Bestellung 4 Stücke:
Lieferzeit 14-21 Tag (e)
1+329.1 EUR
FLUKE T110 FLUKE T110 FLUKE Fluke T110 Datasheet (EN).pdf FLK-T90-DTE.pdf Fluke T110 Datasheet (DE).pdf Fluke T110 Manual (EN).pdf Fluke T110 Manual (DE).pdf Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; 12÷690VAC; 0÷400Hz; IP64; 0Ω÷400kΩ
Type of tester: electrical
Kind of display used: LEDs
Measurement: AC voltage; DC voltage
Phase-to-phase voltage range for phase sequence indication: 12...690V AC
AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring accuracy: ±(3% + 5 digit)
Bandwidth for AC voltage measurements: 0...400Hz
DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
DC voltage measuring accuracy: ±(3% + 5 digit)
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Additional functions: illumination lamp
IP rating: IP64
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Power supply: battery LR03 AAA 1,5V x2
Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button
Body dimensions: 255x78x35mm
Weight with battery: 270g
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
auf Bestellung 30 Stücke:
Lieferzeit 14-21 Tag (e)
1+135.64 EUR
FLUKE T110/VDE FLUKE T110/VDE FLUKE Fluke T110 Datasheet (EN).pdf FLK-T90-DTE.pdf Fluke T110 Datasheet (DE).pdf T110vde_iseng0000.pdf Fluke T110 Manual (EN).pdf Fluke T110 Manual (DE).pdf T110vde_isger0000.pdf Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; 100÷690VAC; 0÷400Hz; IP64; 0Ω÷400kΩ
Type of tester: electrical
Kind of display used: LEDs
Measurement: AC voltage; DC voltage
Phase-to-phase voltage range for phase sequence indication: 100...690V AC
AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring accuracy: ±(3% + 5 digit)
Bandwidth for AC voltage measurements: 0...400Hz
DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
DC voltage measuring accuracy: ±(3% + 5 digit)
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Additional functions: illumination lamp
IP rating: IP64
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Power supply: battery LR03 AAA 1,5V x2
Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button
Body dimensions: 255x78x35mm
Weight with battery: 270g
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
auf Bestellung 11 Stücke:
Lieferzeit 14-21 Tag (e)
1+131.19 EUR
FLUKE T90
+2
FLUKE T90 FLUKE FLK-T90-DTE.pdf Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; 12÷690VAC; 0÷400Hz; IP54; 0Ω÷400kΩ
IP rating: IP54
Body dimensions: 245x64x28mm
Additional functions: illumination lamp
Conform to the norm: CAT II 690V; CAT III 600V; EN 61010
Type of tester: electrical
Power supply: battery LR03 AAA 1,5V x2
Kind of display used: LEDs
Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; polarity identification; polarization indicator
Weight with battery: 180g
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Phase-to-phase voltage range for phase sequence indication: 12...690V AC
Measurement: AC voltage; DC voltage
Bandwidth for AC voltage measurements: 0...400Hz
DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
auf Bestellung 20 Stücke:
Lieferzeit 14-21 Tag (e)
1+93.77 EUR
FLUKE 1630-2 FLUKE 1630-2 FLUKE Category: Clamp Meters - Others
Description: Meter: grounding resistance; pincers type; LCD; (9999)
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)
1+2245.1 EUR
FLUKE T130 FLUKE T130 FLUKE Fluke T130 Datasheet (EN).pdf FLK-T90-DTE.pdf Fluke T130 Datasheet (DE).pdf Fluke T130 Manual (EN).pdf Fluke T130 Manual (DE).pdf Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 6÷690VAC; 0÷400Hz; IP64
Type of tester: electrical
Kind of display used: LCD; LEDs
Display parameters: 3,5 digit
Measurement: AC voltage; DC voltage
Phase-to-phase voltage range for phase sequence indication: 6...690V AC
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring accuracy: ±(3% + 5 digit)
Bandwidth for AC voltage measurements: 0...400Hz
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
DC voltage measuring accuracy: ±(3% + 5 digit)
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Additional functions: illumination lamp
IP rating: IP64
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Power supply: battery LR03 AAA 1,5V x2
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button
Body dimensions: 255x78x35mm
Weight with battery: 270g
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
auf Bestellung 42 Stücke:
Lieferzeit 14-21 Tag (e)
1+197.37 EUR
FLUKE T130/VDE FLUKE T130/VDE FLUKE FLK-T90-DTE.pdf T110vde_iseng0000.pdf T110vde_isger0000.pdf Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 100÷690VAC; 0÷400Hz; IP64
Type of tester: electrical
Kind of display used: LCD; LEDs
Display parameters: 3,5 digit
Measurement: AC voltage; DC voltage
Phase-to-phase voltage range for phase sequence indication: 100...690V AC
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring accuracy: ±(3% + 5 digit)
Bandwidth for AC voltage measurements: 0...400Hz
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
DC voltage measuring accuracy: ±(3% + 5 digit)
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Additional functions: illumination lamp
IP rating: IP64
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Power supply: battery LR03 AAA 1,5V x2
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button
Body dimensions: 255x78x35mm
Weight with battery: 270g
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
auf Bestellung 11 Stücke:
Lieferzeit 14-21 Tag (e)
1+198.34 EUR
FLUKE T150 FLUKE T150 FLUKE FLK-T90-DTE.pdf Fluke T150 Datasheet (EN).pdf Fluke T150 Datasheet (DE).pdf Fluke T150 Manual (EN).pdf Fluke T150 Manual (DE).pdf Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 6÷690VAC; 0÷400Hz; IP64
Type of tester: electrical
Kind of display used: LCD; LEDs
Display parameters: 3,5 digit
Measurement: AC voltage; DC voltage; resistance
Phase-to-phase voltage range for phase sequence indication: 6...690V AC
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring accuracy: ±(3% + 5 digit)
Bandwidth for AC voltage measurements: 0...400Hz
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
DC voltage measuring accuracy: ±(3% + 5 digit)
Resistance measuring range: 1...1999Ω
Resistance measuring accuracy: ±(5%+10 digit)
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Additional functions: illumination lamp
IP rating: IP64
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Power supply: battery LR03 AAA 1,5V x2
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button
Body dimensions: 255x78x35mm
Weight with battery: 270g
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
auf Bestellung 40 Stücke:
Lieferzeit 14-21 Tag (e)
1+223.94 EUR
FLUKE T150/VDE FLUKE T150/VDE FLUKE Fluke T150 Datasheet (EN).pdf FLK-T90-DTE.pdf Fluke T150 Datasheet (DE).pdf T110vde_iseng0000.pdf Fluke T150 Manual (EN).pdf Fluke T150 Manual (DE).pdf T110vde_isger0000.pdf Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 100÷690VAC; 0÷400Hz; IP64
Type of tester: electrical
Kind of display used: LCD; LEDs
Display parameters: 3,5 digit
Measurement: AC voltage; DC voltage; resistance
Phase-to-phase voltage range for phase sequence indication: 100...690V AC
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring accuracy: ±(3% + 5 digit)
Bandwidth for AC voltage measurements: 0...400Hz
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
DC voltage measuring accuracy: ±(3% + 5 digit)
Resistance measuring range: 1...1999Ω
Resistance measuring accuracy: ±(5%+10 digit)
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Additional functions: illumination lamp
IP rating: IP64
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Power supply: battery LR03 AAA 1,5V x2
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button
Body dimensions: 255x78x35mm
Weight with battery: 270g
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
auf Bestellung 27 Stücke:
Lieferzeit 14-21 Tag (e)
1+229.59 EUR
FLUKE 1630-2 FC
+2
FLUKE 1630-2 FC FLUKE 1630-2-FC.pdf FLK-1630-2-INS.pdf Fluke 1630-2 FC Manual EN.pdf Fluke 1630-2 FC Manual DE.pdf Category: Clamp Meters - Others
Description: Meter: grounding resistance; pincers type; LCD; (9999)
Type of meter: grounding resistance
Kind of meter: pincers type
Kind of display used: LCD
Display parameters: (9999)
Measurement: leakage current; resistance
Interface: Bluetooth
Battery/ rechargeable battery: battery 6LR61 9V x1
Alias: 4829532
Resistance measuring range: 25mΩ; 250mΩ; 10Ω; 100Ω; 200Ω; 0.4kΩ; 600Ω; 1.5kΩ
Resistance measuring accuracy: ±(1,5% + 3 digits)
Continuity test: acoustic indication
auf Bestellung 5 Stücke:
Lieferzeit 14-21 Tag (e)
1+2380.92 EUR
FLUKE 787B
+5
FLUKE 787B FLUKE FLK-787B.pdf FLK-787B-INS.pdf Category: Calibrators
Description: Meter: multimeter calibrator; Diode test: 0.3mA@600mV
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010; EN 61243-3:2010
Standard equipment: crocodile clips FLK-AC72; test leads FLK-TL71
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; crocodile clip FLK-AC89; crocodile clip FLK-AC220; crocodile clip FLK-AC283; crocodile clip FLK-AC285; FLK-C510 - soft cover; FLK-FVF-SC2 software; FLK-TL225 set
Related items: POM-5900A/POM; POM-6173A; POM-7519A
Dimensions: 203x100x50mm
Measuring instrument features: automatic and manual setting of step function; HOLD function; MIN/MAX/MEAN/REL function; simultaneous readout in mA and % of range; source DC current / calibrate loop current, source/simulate
Type of meter: multimeter calibrator
Continuity test: acoustic indication; <100Ω
AC current measuring range: 0.001mA...1A
Resistance measuring range: 100mΩ...400Ω; 4kΩ; 400kΩ; 4MΩ; 40MΩ
DC current measuring range: 1µA...30mA; 1A
DC voltage measuring range: 1...400mV; 4V; 40V; 400V; 1kV
AC voltage measuring range: 0.1...400mV; 4V; 40V; 400V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.99kHz
Diode test: 0.3mA @600mV
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Software: Fluke Connect (FLK-IR3000FC)
Frequency measuring accuracy: ±(0.005%+1 digit)
AC current measuring accuracy: ±(1% + 2 digit)
DC voltage measuring accuracy: ±(0.1% + 1 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(0.7% + 2 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x4
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)
1+1881.98 EUR
FLUKE 789
+2
FLUKE 789 FLUKE Fluke 789 Datasheet (EN).pdf 10591-eng.pdf 6001874B-EN-FC-Reasons-Why-Flyer-w.pdf 6001874B-de-FC-Reasons-Why-Flyer-w.pdf Fluke 789 Datasheet (DE).pdf Fluke 789 Manual (EN).pdf Fluke 789 Manual (DE).pdf Category: Calibrators
Description: Meter: multimeter calibrator; Diode test: 0.3mA@600mV
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010; EN 61243-3:2010
Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; crocodile clip FLK-AC89; crocodile clip FLK-AC220; crocodile clip FLK-AC283; crocodile clip FLK-AC285; FLK-C510 - soft cover; FLK-FVF-SC2 software; FLK-TL225 set
Related items: POM-5900A/POM; POM-6173A; POM-7519A
Interface: IrDA
Dimensions: 203x100x50mm
Measuring instrument features: 0% or 100% of signal value (4mA, 20mA) source function; 24V loop supply voltage; automatic and manual setting of step function; HART range with loop and built-in 250Ω resistor; HOLD function; impact resistant holster; MIN/MAX/MEAN/REL function; simultaneous readout in mA and % of range; source DC current / calibrate loop current, source/simulate
Type of meter: multimeter calibrator
Power supply: battery LR6 AA 1,5V x4
Continuity test: acoustic indication; <100Ω
Kind of display used: LCD
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; resistance
AC current measuring range: 0.001mA...1A
Resistance measuring range: 100mΩ...400Ω; 4kΩ; 400kΩ; 4MΩ; 40MΩ
DC current measuring range: 1µA...30mA; 1A
DC voltage measuring range: 1...400mV; 4V; 40V; 400V; 1kV
AC voltage measuring range: 0.1...400mV; 4V; 40V; 400V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.99kHz
Diode test: 0.3mA @600mV
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Software: Fluke Connect (FLK-IR3000FC)
Frequency measuring accuracy: ±(0.005%+1 digit)
AC current measuring accuracy: ±(1% + 2 digit)
DC voltage measuring accuracy: ±(0.1% + 1 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1.2% + 4 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)
1+2154.47 EUR
FLUKE-110/ERTA FLUKE-110/ERTA FLUKE FLK-110_EN.pdf Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.32x/s
Type of meter: digital multimeter
Measurement: AC voltage; continuity; DC voltage; resistance
Kind of display used: LCD
Display parameters: (6000)
Bargraph: 33 segm. 32x/s
DC voltage measuring range: 600mV; 6V; 60V; 600V
DC voltage measuring accuracy: ±(0.5% + 2 digit)
AC voltage measuring range: 600mV; 6V; 60V; 600V
AC voltage measuring accuracy: ±(1% + 3 digit)
True effective value measurement: True RMS AC
Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
Resistance measuring accuracy: ±(0.9%+1 digit)
Continuity test: acoustic indication; <20Ω
Pollution degree: 2
Weight with battery: 350g
Power supply: battery 6F22 9V x1
Standard equipment: test leads TL75
Conform to the norm: CAT III 600V; EN 61010
Dimensions (W x H x D): 96x160x46mm
Measuring instrument features: MIN/MAX/MEDIUM function; pocket size
Battery/ rechargeable battery: battery 6F22 9V x1
Manufacturer series: Fluke 110
Illumination: yes
auf Bestellung 20 Stücke:
Lieferzeit 14-21 Tag (e)
1+201.66 EUR
FLUKE 88V/A
+13
FLUKE 88V/A FLUKE FLK-88V-A.PDF 88v_____umeng0100.pdf 88v_____umger0100.pdf Category: Portable digital multimeters
Description: Digital multimeter; LCD; VDC: 0÷1kV; VAC: 0÷1kV; I DC: 0÷10A; 0÷50MΩ
Type of meter: digital multimeter
Kind of display used: LCD
Bargraph: yes
DC current measuring range: 0...10A
AC current measuring range: 0...10A
Measuring instrument features: auto and manual ranging; HOLD function; MIN/MAX/MEAN/REL function; PEAK HOLD function; settable MIN/MAX alarm thresholds
DC voltage measuring range: 0...1kV
AC voltage measuring range: 0...1kV
True effective value measurement: True RMS AC
Resistance measuring range: 0...50MΩ
Capacitance measuring range: 0...10000µF
Frequency measuring range: 0...200kHz
Temperature measuring range: -200...1090°C
Continuity test: acoustic indication
Diode test: 3V
Standard equipment: automotive back probe pins 2pcs; crocodile clips FLK-AC285; FLK-80BK-A drop-like K-type temperature probe; hard case FLK-800; holster; insulation piercing clip; magnetic hanging strap FLK-TOOLPAK; probe FLK-RPM80; test leads FLK-TL224 SureGrip; test probes FLK-TP220
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Battery/ rechargeable battery: battery 6F22 9V x1
Dimensions (W x H x D): 86x186x32mm
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)
1+1246.83 EUR
FLUKE 279FC/IFLEX
+2
FLUKE 279FC/IFLEX FLUKE Fluke 279 FC Datasheet (EN).pdf Fluke 279 FC Datasheet (DE).pdf Fluke 279 FC Manual (EN).pdf Fluke 279 FC Manual (DE).pdf Category: Portable digital multimeters
Description: Digital multimeter with infrared camera; Bluetooth; Plug: EU
Type of meter: digital multimeter with infrared camera
Interface: Bluetooth
Measurement: AC current; AC voltage; capacitance; DC voltage; frequency; non-contact temeprature (IR); resistance
DC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
AC current measuring range: 100mA...999.9A; 2.5kA
Resistance measuring range: 600Ω...50MΩ
Capacitance measuring range: 1000nF...9999µF
Frequency measuring range: 99.99...999.9Hz
Non-contact temperature measuring range: -10...200°C
Diode test: 2V
Continuity test: acoustic indication; <25Ω
Standard equipment: battery charger/power supply; case; FLK-I2500-18 flexible current probe; FLK-TL175 test leads
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5677B; POM-5899A; POM-7519A
Plug variant: EU
Refresh rate: 8Hz
Emissivity value: 0,95 (fixed)
Focusing: focus free
Dimensions (W x H x D): 93.9x215.9x57.1mm
Camera resolution: 80x60
Thermal sensitivity (NETD): ≤0.2°C
Battery/ rechargeable battery: rechargeable battery Li-Ion 7,4V 3000mAh x1
Connectors for the country: Great Britain
auf Bestellung 3 Stücke:
Lieferzeit 14-21 Tag (e)
1+1679.76 EUR
FLUKE 3000 FC
+5
FLUKE 3000 FC FLUKE FLK-3000FC-DTE.pdf 6001874B-EN-FC-Reasons-Why-Flyer-w.pdf 6001874B-de-FC-Reasons-Why-Flyer-w.pdf FLK-3000FC-INS.pdf Category: Portable digital multimeters
Description: Digital multimeter; Bluetooth; LCD; VDC: 600mV,6V,60V,600V,1kV
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Continuity test: acoustic indication
True effective value measurement: True RMS
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Dimensions (W x H x D): 93x207x48mm
AC current measuring range: 60mA; 400mA
Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 60mA; 400mA
DC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 9.999Hz; 99.99Hz; 999.9Hz; 99.99kHz
Capacitance measuring range: 1µF; 10µF; 100µF; 9.999mF
Diode test: 2V
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Software: compatible Android; Fluke Connect
Frequency measuring accuracy: ±(0.1%+1 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
DC current measuring accuracy: ±(0.5% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.5%+1 digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x3
IP rating: IP54
Interface: Bluetooth
Related items: FLK-A3001FC-KITCAR; POM-5677B; POM-5899A; POM-7519A
Standard equipment: crocodile clips FLK-AC175; FLK-TL175 test leads
Measuring instrument features: 20m range; auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function
Type of meter: digital multimeter
Weight with battery: 340g
auf Bestellung 3 Stücke:
Lieferzeit 14-21 Tag (e)
1+540.97 EUR
FLUKE 1587T
+5
FLUKE 1587T FLUKE 15x7____umeng0200.pdf 15x7____umger0200.pdf Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Optional equipment: FLK-C25 soft cover
Continuity test: acoustic indication; <25Ω
Temperature measurement resolution: 0.1°C
Temperature measuring range: -40...537°C
True effective value measurement: True RMS
Measurement: AC current; capacitance; DC current; frequency; insulation resistance; resistance; temperature
Dimensions (W x H x D): 100x203x50mm
Test voltage: 50V; 100V
AC current measuring range: 10µA...60mA; 400mA
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 10µA...60mA; 400mA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1mA @6V
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Insulation resistance measuring ranges: 10kΩ...100MΩ
Display parameters: (6000)
Frequency measuring accuracy: ±(0.1%+1 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 2 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+2 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x4
IP rating: IP40
Illumination: yes
Standard equipment: crocodile clips FLK-AC285; FLK-80BK-A drop-like K-type temperature probe; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; for telecommunication; HOLD function; indicates incorrect connection of test leads; insulation resistance test; MIN/MAX/MEDIUM function
Type of meter: digital multimeter
auf Bestellung 4 Stücke:
Lieferzeit 14-21 Tag (e)
1+1220.48 EUR
Fluke 123B
+3
Fluke 123B FLUKE Fluke 120B Series Datasheet EN.pdf Fluke 120B Series Datasheet DE.pdf FLK-123B-INS.pdf Fluke 120B Series Manual EN.pdf Fluke 120B Series Manual DE.pdf Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div
Kind of display used: colour; LCD TFT 5,7"
Sampling: 40Msps
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Resistance measuring accuracy: ±(0.6%+5 digit)
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Continuity test: acoustic indication
Diode test: 0.5mA @2.8V
Dimensions: 259x132x55mm
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Additional functions: multimeter
IP rating: IP51
Related items: POM-72941; POM-72942
Manufacturer series: FLUKE 120B
Band: 20MHz
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Time base: 20n...60s/div
Number of channels: 2
Type of oscilloscope: scopemeter
Plug variant: EU
Display resolution: 640x480
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)
1+2800.96 EUR
Fluke 123B/S
+15
Fluke 123B/S FLUKE Fluke 120B Series Datasheet EN.pdf Fluke 120B Series Datasheet DE.pdf Fluke 120B Series Manual EN.pdf FLK-123B-INS.pdf Fluke 120B Series Manual DE.pdf Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div
Kind of display used: colour; LCD TFT 5,7"
Sampling: 40Msps
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Resistance measuring accuracy: ±(0.6%+5 digit)
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Continuity test: acoustic indication
Diode test: 0.5mA @2.8V
Dimensions: 259x132x55mm
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Additional functions: multimeter
IP rating: IP51
Related items: POM-72941; POM-72942
Manufacturer series: FLUKE 120B
Band: 20MHz
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Software: Fluke View
Time base: 20n...60s/div
Number of channels: 2
Type of oscilloscope: scopemeter
Plug variant: EU
Display resolution: 640x480
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)
1+3601.68 EUR
Fluke 124B
+16
Fluke 124B FLUKE Fluke 120B Series Datasheet EN.pdf Fluke 120B Series Datasheet DE.pdf Fluke 120B Series Manual EN.pdf FLK-123B-INS.pdf Fluke 120B Series Manual DE.pdf Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Kind of display used: colour; LCD TFT 5,7"
Sampling: 40Msps
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Resistance measuring accuracy: ±(0.6%+5 digit)
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Continuity test: acoustic indication
Diode test: 0.5mA @2.8V
Dimensions: 259x132x55mm
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Additional functions: multimeter
IP rating: IP51
Related items: POM-72941; POM-72942
Manufacturer series: FLUKE 120B
Band: 40MHz
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Time base: 10n...60s/div
Number of channels: 2
Type of oscilloscope: scopemeter
Plug variant: EU
Display resolution: 640x480
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)
1+3361.67 EUR
Fluke 124B/S
+15
Fluke 124B/S FLUKE Fluke 120B Series Datasheet EN.pdf Fluke 120B Series Datasheet DE.pdf FLK-123B-INS.pdf Fluke 120B Series Manual EN.pdf Fluke 120B Series Manual DE.pdf Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Kind of display used: colour; LCD TFT 5,7"
Sampling: 40Msps
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Resistance measuring accuracy: ±(0.6%+5 digit)
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Continuity test: acoustic indication
Diode test: 0.5mA @2.8V
Dimensions: 259x132x55mm
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Additional functions: multimeter
IP rating: IP51
Related items: POM-72941; POM-72942
Manufacturer series: FLUKE 120B
Band: 40MHz
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Software: Fluke View
Time base: 10n...60s/div
Number of channels: 2
Type of oscilloscope: scopemeter
Plug variant: EU
Display resolution: 640x480
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)
1+4140.32 EUR
Fluke 125B
+5
Fluke 125B FLUKE Fluke 120B Series Datasheet EN.pdf Fluke 120B Series Datasheet DE.pdf FLK-123B-INS.pdf Fluke 120B Series Manual EN.pdf Fluke 120B Series Manual DE.pdf Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Kind of display used: colour; LCD TFT 5,7"
Sampling: 40Msps
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Resistance measuring accuracy: ±(0.6%+5 digit)
Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Continuity test: acoustic indication
Diode test: 0.5mA @2.8V
Dimensions: 259x132x55mm
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; FLK-I400S - current clamp
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Additional functions: multimeter
IP rating: IP51
Related items: POM-72941; POM-72942
Manufacturer series: FLUKE 120B
Band: 40MHz
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Time base: 10n...60s/div
Number of channels: 2
Type of oscilloscope: scopemeter
Plug variant: EU
Display resolution: 640x480
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)
1+4014.22 EUR
Fluke 125B/S
+16
Fluke 125B/S FLUKE Fluke 120B Series Datasheet EN.pdf Fluke 120B Series Datasheet DE.pdf Fluke 120B Series Manual EN.pdf FLK-123B-INS.pdf Fluke 120B Series Manual DE.pdf Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Kind of display used: colour; LCD TFT 5,7"
Sampling: 40Msps
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Resistance measuring accuracy: ±(0.6%+5 digit)
Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Continuity test: acoustic indication
Diode test: 0.5mA @2.8V
Dimensions: 259x132x55mm
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; FLK-I400S - current clamp; magnetic hanging strap; screen protector
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Additional functions: multimeter
IP rating: IP51
Manufacturer series: FLUKE 120B
Band: 40MHz
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Software: Fluke View
Time base: 10n...60s/div
Number of channels: 2
Type of oscilloscope: scopemeter
Plug variant: EU
Display resolution: 640x480
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)
1+4691.5 EUR
FLUKE 1587 FC
+3
FLUKE 1587 FC FLUKE Fluke 1587 FC Datasheet (EN).pdf Fluke 1587 FC Datasheet (DE).pdf 15x7____umeng0200.pdf Fluke 1587 FC Manual (EN).pdf 15x7____umger0200.pdf Fluke 1587 FC Manual (DE).pdf Category: Portable digital multimeters
Description: Digital multimeter; Bluetooth; LCD; (6000); I DC: 0.01÷60mA,400mA
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Optional equipment: FLK-C25 soft cover
Continuity test: acoustic indication; <25Ω
Temperature measurement resolution: 0.1°C
Temperature measuring range: -40...537°C
True effective value measurement: True RMS AC
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; insulation resistance; resistance; temperature
Dimensions (W x H x D): 100x203x50mm
Test voltage: 500V
AC current measuring range: 10µA...60mA; 400mA
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 10µA...60mA; 400mA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1mA @6V
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ
Display parameters: (6000)
Frequency measuring accuracy: ±(0.1%+1 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 2 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+2 digit)
Insulation resistance measuring accuracy: ±(1.5% + 5digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x4
IP rating: IP40
Interface: Bluetooth
Illumination: yes
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5906A; POM-5907A; POM-6041B
Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test
Type of meter: digital multimeter
Weight with battery: 550g
auf Bestellung 13 Stücke:
Lieferzeit 14-21 Tag (e)
1+1314.37 EUR
Fluke 373
+6
Fluke 373 FLUKE flk-373.pdf 373_____umeng0000.pdf 373_____umger0000.pdf Category: Meters and AC Clamp Probes
Description: Meter: multifunction; digital,pincers type; LCD; Øcable: 32mm
Type of meter: multifunction
Kind of meter: digital; pincers type
Max. diameter of measured cable: 32mm
Kind of display used: LCD
AC current measuring range: 100mA...600A
Measuring instrument features: automatic power-off; HOLD function
AC current measuring accuracy: ±(2% + 5 digit)
DC voltage measuring range: 100mV...600V
DC voltage measuring accuracy: ±(1% + 5 digit)
AC voltage measuring range: 100mV...600V
AC voltage measuring accuracy: ±(1% + 5 digit)
Resistance measuring accuracy: ±(1%+5 digit)
True effective value measurement: True RMS
Resistance measuring range: 100mΩ...600Ω; 6kΩ
Capacitance measuring range: 0.1...10µF; 100µF; 1mF
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
Continuity test: acoustic indication; <30Ω
Pollution degree: 2
Body dimensions: 232x85x45mm
Weight without batteries: 370g
Power supply: battery LR6 AA 1,5V x2
Standard equipment: case; test leads
Optional equipment: crocodile clip FLK-AC89; crocodile clip FLK-AC220; FLK-TL175 test leads; FLK-TL220 set; test leads FLK-TL75
Measurement: AC current; AC voltage; capacitance; DC voltage; resistance
Conform to the norm: CAT III 600V; CAT IV 300V; EN 61010
Related items: POM-5913; POM-6173A; POM-7519A
Illumination: yes
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)
1+460.53 EUR
FLUKE 355
+4
FLUKE 355 FLUKE FLK-353-FLK-355.PDF 353_355_umeng0000.pdf 353_355_umger0000.pdf Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 58mm; LCD
Related items: POM-5673B; POM-5907A; POM-6041B
Illumination: yes
Dimensions: 300x98x52mm
Standard equipment: crocodile clips; soft cover FLK-C43; test leads
Measuring instrument features: HOLD function; MIN/MAX, MAX-MIN, MEAN function
Type of meter: multifunction
Weight without batteries: 814g
Continuity test: acoustic indication
Max. diameter of measured cable: 58mm
True effective value measurement: True RMS
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; inrush current; resistance
Kind of meter: digital; pincers type
AC current measuring range: 40A; 400A; 2kA
Resistance measuring range: 0.4kΩ; 4kΩ; 40kΩ; 400kΩ
DC current measuring range: 40A; 400A; 2kA
DC voltage measuring range: 4V; 40V; 400V; 1kV
AC voltage measuring range: 4V; 40V; 400V; 750V; 1kV
Frequency measuring range: 5Hz; 100Hz; 1kHz
Frequency measuring accuracy: ±(0.5%+5 digit)
AC current measuring accuracy: ±(1.5% + 5 digit)
DC voltage measuring accuracy: ±(1% + 5 digit)
DC current measuring accuracy: ±(1.5% + 5 digit)
AC voltage measuring accuracy: ±(1% + 5 digit)
Resistance measuring accuracy: ±(1%+5 digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x6
auf Bestellung 3 Stücke:
Lieferzeit 14-21 Tag (e)
1+1363.46 EUR
FLK-115/TLK-225-1 FLK-115/TLK-225-1 FLUKE Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
auf Bestellung 113 Stücke:
Lieferzeit 14-21 Tag (e)
1+326.58 EUR
FLK-IB117
+4
FLK-IB117 FLUKE Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Conform to the norm: CAT III 600V; EN 61010
Manufacturer series: Fluke 110
Optional equipment: FLK-80BK-A drop-like K-type temperature probe; FLK-80PJ-EXT drop-like J-type temperature probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Continuity test: acoustic indication; <20Ω
Pollution degree: 2
True effective value measurement: True RMS AC
Bargraph: 33 segm. 32x/s
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Dimensions (W x H x D): 84x167x46mm
AC current measuring range: 1mA...6A; 10A; (20A <30s)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
DC current measuring range: 1mA...6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1.2mA @2.7V
Battery/ rechargeable battery: battery 6LR61 9V x1
Display parameters: 3,75 digit (6000)
Frequency measuring accuracy: ±(0.1%+2 digit)
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring accuracy: ±(0.5% + 2 digit)
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Kind of display used: LCD
Power supply: battery 6LR61 9V x1
Standard equipment: 3x insulated screwdrivers; FLK-TL75 test leads
Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); HOLD function; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Type of meter: digital multimeter
Weight with battery: 550g
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)
1+472.93 EUR
FLUKE 27-II
+5
FLUKE 27-II FLUKE FLK-27-2.pdf 2x_2____umeng0100.pdf 2x_2____umger0100.pdf Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; IP67
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Continuity test: acoustic indication
Duty cycle factor: 0...99.9%
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Temperature measurement resolution: 0.1°C
Conductance measurement: 0.01...60nS
Temperature measuring range: -200...1090°C
Bargraph: 33 segm. 40x/s
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Dimensions (W x H x D): 100x198x63.5mm
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Diode test: 1mA @2.8V
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Display parameters: (6000)
Frequency measuring accuracy: ±(0.005%+1 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 2 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(2% + 3 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x3
IP rating: IP67
Illumination: yes
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Standard equipment: test leads
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; HOLD function; MIN/MAX/MEAN/REL function; shock-resistant case
Type of meter: digital multimeter
Weight with battery: 517g
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)
1+1035.42 EUR
FLUKE 365
+12
FLUKE 365 FLUKE Fluke 365 Datasheet EN.pdf Fluke 365 Datasheet DE.pdf Fluke 365 Manual EN.pdf Fluke 365 Manual DE.pdf Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 18mm; LCD
Type of meter: multifunction
Measurement: AC current; AC voltage; DC current; DC voltage; resistance
Max. diameter of measured cable: 18mm
Kind of display used: LCD
DC voltage measuring range: 100mV...600V
DC voltage measuring accuracy: ±(1.5% + 5 digit)
AC voltage measuring range: 100mV...600V
AC voltage measuring accuracy: ±(1% + 5 digit)
DC current measuring range: 100mA...200A
DC current measuring accuracy: ±(2% + 5 digit)
AC current measuring range: 100mA...200A
AC current measuring accuracy: ±(2% + 5 digit)
True effective value measurement: True RMS
Resistance measuring range: 100mΩ...600Ω; 6kΩ
Resistance measuring accuracy: ±(1%+5 digit)
Continuity test: acoustic indication; <30Ω
Dimensions: 225x65x46mm
Weight with battery: 275g
Power supply: battery LR6 AA 1,5V x2
Standard equipment: case; fixed test leads; FLK-TL75 test leads
Optional equipment: crocodile clip FLK-AC220; crocodile clip FLK-AC285; FLK-C43 soft cover; FLK-TL220 set; test leads FLK-TL71; test leads FLK-TL224 SureGrip
Additional functions: torch
Measuring instrument features: automatic power-off; current clamp can be detached from the meter for measurements in hard-to-reach places; LED for measurement spot illumination
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Illumination: yes
Kind of meter: digital; pincers type
auf Bestellung 5 Stücke:
Lieferzeit 14-21 Tag (e)
1+462.71 EUR
FLUKE 28-II
+7
FLUKE 28-II FLUKE Fluke 28-II Datasheet EN.pdf Fluke 28-II Datasheet DE.pdf 2x_2____umeng0100.pdf Fluke 28-II Manual EN.pdf 2x_2____umger0100.pdf Fluke 28-II Manual DE.pdf Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; True RMS
Type of meter: digital multimeter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Kind of display used: LCD
Display parameters: (6000)
Bargraph: 33 segm. 40x/s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.05% + 1 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1% + 4 digit)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC current measuring accuracy: ±(0.2% + 2 digit)
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
AC current measuring accuracy: ±(1% + 2 digit)
True effective value measurement: True RMS
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Capacitance measuring accuracy: ±(1%+ 2 digit)
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
Temperature measuring range: -200...1090°C
Temperature measurement accuracy: ±(1% + 10 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Temperature measurement resolution: 0.1°C
Conductance measurement: 0.01...60nS
Duty cycle factor: 0...99.9%
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Diode test: 1mA @2.8V
Continuity test: acoustic indication
IP rating: IP67
Weight with battery: 517g
Power supply: battery LR6 AA 1,5V x3
Standard equipment: test leads
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Dimensions (W x H x D): 100x198x63.5mm
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Illumination: yes
auf Bestellung 4 Stücke:
Lieferzeit 14-21 Tag (e)
1+1031.86 EUR
FLUKE 28 II EX
+5
FLUKE 28 II EX FLUKE Fluke 28-II Datasheet EN.pdf Fluke 28-II Datasheet DE.pdf 2x_2____umeng0100.pdf Fluke 28-II Manual EN.pdf Fluke 28-II Manual DE.pdf 2x_2____umger0100.pdf Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/19999); Bargraph: 33segm.40x/s
Type of meter: digital multimeter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Kind of display used: LCD
Display parameters: (6000/19999)
Bargraph: 33 segm. 40x/s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.05% + 1 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1% + 4 digit)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC current measuring accuracy: ±(0.2% + 2 digit)
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
AC current measuring accuracy: ±(1% + 2 digit)
True effective value measurement: True RMS
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Capacitance measuring accuracy: ±(1%+ 2 digit)
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
Temperature measuring range: -200...1090°C
Temperature measurement accuracy: ±(1% + 10 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Temperature measurement resolution: 0.1°C
Conductance measurement: 0.01...60nS
Duty cycle factor: 0...99.9%
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Diode test: 1mA @2.8V
Continuity test: acoustic indication
IP rating: IP67
Weight with battery: 517g
Power supply: battery LR03 AAA 1,5V x3
Standard equipment: test leads
Optional equipment: crocodile clip FLK-AC285; FLK-80BK-A drop-like K-type temperature probe; FLK-80PK-1 drop-like K-type temperature probe; FLK-80PK-8 drop-like K-type temperature probe; FLK-80PK-9 drop-like K-type temperature probe; FLK-80PK-27 drop-like K-type temperature probe; FLK-C101 hard case; FLK-TL175 test leads; test leads FLK-TL71
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Dimensions (W x H x D): 100x198x63.5mm
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; intrinsic safety; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case
Battery/ rechargeable battery: battery LR03 AAA 1,5V x3
Illumination: yes
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)
1+2477.37 EUR
FLUKE 381
+10
FLUKE 381 FLUKE Fluke 381 Datasheet EN.pdf Fluke 381 Datasheet DE.pdf Fluke 381 Manual EN.pdf Fluke 381 Manual DE.pdf Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Optional equipment: FLK-TL175 test leads; FLK-TL223 accessory set
Related items: POM-5913; POM-6173A; POM-7519A
Measuring instrument features: automatic power-off; flexible current probe; HOLD function; MIN/MAX/MEDIUM function; wireless display (range up to 10m)
Type of meter: multifunction
Continuity test: acoustic indication; <30Ω
Max. diameter of measured cable: 34mm
True effective value measurement: True RMS
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; inrush current; resistance
Kind of meter: digital; pincers type
AC current measuring range: 100mA...1kA
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ
DC current measuring range: 100mA...1kA
DC voltage measuring range: 100mV...600V; 1kV
AC voltage measuring range: 100mV...600V; 1kV
Frequency measuring range: 5...500Hz
CF crest factor: 1.42 @ 1kA; 2.5 @ 600A; 3 @ 500A
Frequency measuring accuracy: ±(0.5%+5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
DC voltage measuring accuracy: ±(1.5% + 5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
AC voltage measuring accuracy: ±(1.5% + 5 digit)
Resistance measuring accuracy: ±(1%+5 digit)
Kind of display used: LCD
Power supply: battery LR03 AAA 1,5V x5
Body dimensions: 277x88x43mm
Illumination: yes
auf Bestellung 7 Stücke:
Lieferzeit 14-21 Tag (e)
1+1031.37 EUR
FLUKE 393 FC
+2
FLUKE 393 FC FLUKE FLK-393FC-EN.pdf Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Interface: Bluetooth
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x2
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Software: Fluke Connect
True effective value measurement: True RMS
Measurement: AC current; AC voltage; capacitance; continuity; current (with current clamps); DC current; DC voltage; frequency; inrush current; peak current; resistance
Kind of meter: digital; pincers type
AC current measuring range: 100mA...999.9A
Resistance measuring range: 600Ω; 6kΩ; 60kΩ
DC current measuring range: 100mA...999.9A
DC voltage measuring range: 600V; 1.5kV
AC voltage measuring range: 600V; 1kV
Frequency measuring range: 5...500Hz
Capacitance measuring range: 0.1...100µF; 1mF
CF crest factor: 1.42k @ 2.5kA; 2.5k @ 600A; 3k @ 1.1kA
Frequency measuring accuracy: ±(0.5%+5 digit)
Capacitance measuring accuracy: ±(1%+ 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
DC voltage measuring accuracy: ±(1% + 5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
AC voltage measuring accuracy: ±(1% + 5 digit)
Resistance measuring accuracy: ±(1%+5 digit)
Conform to the norm: CAT III 1500V; CAT IV 600V; EN 61010
Illumination: yes
Dimensions: 281x84x49mm
Standard equipment: case; iFlex2500-18 - current clamp; magnetic hanging strap; test leads ( 2pcs.)
Measuring instrument features: AUTO HOLD; automatic power-off; flexible current probe up to 2500A; HOLD function; MIN/MAX/AVG function; polarization indicator
Type of meter: multifunction
Weight with battery: 520g
Continuity test: acoustic indication; <30Ω
Pollution degree: 2
Max. diameter of measured cable: 34mm
auf Bestellung 9 Stücke:
Lieferzeit 14-21 Tag (e)
1+963.38 EUR
FLUKE 83V
+5
FLUKE 83V FLUKE Fluke 83V 87V Datasheet EN.pdf Fluke 83V 87V Datasheet DE.pdf fluke 83 V Manual (EN).pdf fluke 83 V Manual (DE).pdf Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; 0.01÷60S
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: (6000)
Bargraph: 33 segm. 40x/s
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
Measuring instrument features: auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; test leads resistance compensation
DC current measuring accuracy: ±(0.4% + 2 digit)
AC current measuring accuracy: ±(1.2% + 2 digit)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.1% + 1 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(0.7% + 4 digit)
Resistance measuring accuracy: ±(0.4%+1 digit)
True effective value measurement: True RMS AC
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Capacitance measuring accuracy: ±(1%+ 2 digit)
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
Continuity test: acoustic indication
Diode test: 1mA @3V
Pollution degree: 2
Weight with battery: 600g
Power supply: battery 6F22 9V x1
Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
IP rating: IP30
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Battery/ rechargeable battery: battery 6F22 9V x1
Illumination: yes
Conductance measuring accuracy: ±(1% + 10digit)
Dimensions (W x H x D): 95x200x48mm
Conductance measurement: 0.01...60S
auf Bestellung 6 Stücke:
Lieferzeit 14-21 Tag (e)
1+828.27 EUR
FLUKE 87-V
+6
FLUKE 87-V FLUKE Fluke 87 V Datasheet (EN).pdf Fluke 87 V Datasheet (DE).pdf Fluke 87 V Manual (EN).pdf Fluke 87 V Manual (DE).pdf Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Standard equipment: crocodile clips FLK-AC72; FLK-80BK-A drop-like K-type temperature probe; FLK-TL175 test leads
Type of meter: digital multimeter
Weight with battery: 600g
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Continuity test: acoustic indication
Pollution degree: 2
Temperature measurement resolution: 0.1°C
Conductance measurement: 0.01...60nS
Temperature measuring range: -200...1090°C
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Dimensions (W x H x D): 95x200x48mm
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Diode test: 1mA @3V
Battery/ rechargeable battery: battery 6F22 9V x1
Display parameters: (6000/20000)
Frequency measuring accuracy: ±(0.005%+1 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
AC current measuring accuracy: ±(1% + 2 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Kind of display used: LCD
Power supply: battery 6F22 9V x1
IP rating: IP30
Illumination: yes
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
auf Bestellung 15 Stücke:
Lieferzeit 14-21 Tag (e)
1+844.27 EUR
FLUKE 87-V MAX FLUKE 87-V MAX FLUKE FLK-87VMAX.pdf Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B
Standard equipment: crocodile clip FLK-AC175 x2; FLK-80BK-A drop-like K-type temperature probe; FLK-TL175 test leads
Type of meter: digital multimeter
Weight with battery: 700g
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Continuity test: acoustic indication
Pollution degree: 2
Temperature measurement resolution: 0.1°C
Conductance measurement: 0.01...60nS
Temperature measuring range: -200...1090°C
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Dimensions (W x H x D): 63x198x100mm
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Diode test: 1mA @3V
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Display parameters: (6000/20000)
Frequency measuring accuracy: ±(0.005%+1 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
AC current measuring accuracy: ±(1% + 2 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
DC current measuring accuracy: ±(0.2% + 4 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x3
IP rating: IP67
Illumination: yes
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
auf Bestellung 8 Stücke:
Lieferzeit 14-21 Tag (e)
1+939.51 EUR
FLUKE-87V-MAX/E2 KIT
+3
FLUKE-87V-MAX/E2 KIT FLUKE FLK-87VMAX.pdf Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B
Standard equipment: crocodile clip FLK-AC220 x2; FLK-80BK-A drop-like K-type temperature probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; test leads FLK-TL-224; test probes FLK-TL238
Type of meter: digital multimeter
Weight with battery: 700g
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Continuity test: acoustic indication
Pollution degree: 2
Temperature measurement resolution: 0.1°C
Conductance measurement: 0.01...60nS
Temperature measuring range: -200...1090°C
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Dimensions (W x H x D): 63x198x100mm
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Diode test: 1mA @3V
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Display parameters: (6000/20000)
Frequency measuring accuracy: ±(0.005%+1 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
AC current measuring accuracy: ±(1% + 2 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
DC current measuring accuracy: ±(0.2% + 4 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x3
IP rating: IP67
Illumination: yes
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
auf Bestellung 3 Stücke:
Lieferzeit 14-21 Tag (e)
1+1109.39 EUR
FLK-87VMAX-PVLEAD1
+3
FLK-87VMAX-PVLEAD1 FLUKE Category: PV and EVSE Testers and Meters
Description: Meter: digital multimeter; VAC accuracy: ±(0.7%+4digit); IP67
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Continuity test: acoustic indication
Temperature measurement resolution: 0.1°C
Conductance measurement: 0.01...60nS
Temperature measuring range: -200...1090°C
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Dimensions (W x H x D): 63x198x100mm
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Diode test: 1mA @3V
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Display parameters: (6000/20000)
Frequency measuring accuracy: ±(0.005%+1 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
AC current measuring accuracy: ±(1% + 2 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
DC current measuring accuracy: ±(0.2% + 4 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x3
IP rating: IP67
Illumination: yes
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B
Standard equipment: crocodile clip FLK-AC175 x2; FLK-80BK-A drop-like K-type temperature probe; FLK-TL175 test leads; test leads MC4
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
Type of meter: digital multimeter
Weight with battery: 700g
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)
1+1063.71 EUR
FLUKE 374 FC
+9
FLUKE 374 FC FLUKE Fluke 374 FC Datasheet (EN).pdf Fluke 374 FC Datasheet (DE).pdf Fluke 374 FC Manual (EN).pdf Fluke 374 FC Manual (DE).pdf Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Type of meter: multifunction
Kind of display used: LCD
Resistance measuring range: 100mΩ...600Ω; 6kΩ
Capacitance measuring range: 0.1...100µF; 1mF
DC voltage measuring range: 100mV...600V
DC voltage measuring accuracy: ±(1% + 5 digit)
AC voltage measuring range: 100mV...600V
AC voltage measuring accuracy: ±(1.5% + 5 digit)
Frequency measuring range: 5...500Hz
Frequency measuring accuracy: ±(0.5%+5 digit)
DC current measuring range: 100mA...600A
DC current measuring accuracy: ±(2% + 5 digit)
AC current measuring range: 100mA...600A
AC current measuring accuracy: ±(2% + 5 digit)
Capacitance measuring accuracy: ±(1%+ 4 digit)
Resistance measuring accuracy: ±(1%+5 digit)
Test: diodes
Continuity test: acoustic indication; <30Ω
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; inrush current; resistance
Interface: Bluetooth
Software: Fluke Connect
Illumination: yes
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Power supply: battery LR6 AA 1,5V x2
Dimensions: 246x83x43mm
Measuring instrument features: automatic power-off; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; transfer measurement data wireless
Optional equipment: FLK-C43 soft cover; FLK-I2500-10 flexible current probe; FLK-I2500-18 flexible current probe
Related items: POM-5913; POM-6173A; POM-7519A
Pollution degree: 2
Max. diameter of measured cable: 34mm
Weight with battery: 388g
True effective value measurement: True RMS
Kind of meter: digital; pincers type
CF crest factor: 2.5 @ 600A
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)
1+639.21 EUR
FLUKE 772 FLK-770-DTE.PDF Fluke 772 Datasheet (EN).pdf Fluke 772 Datasheet (DE).pdf Fluke 772 Manual (EN).pdf Fluke 772 Manual (DE).pdf
Hersteller: FLUKE
Category: Clamp Meters - Others
Description: Meter: current loop; pincers type; LCD; IP40; Illumin: yes
Type of meter: current loop
Kind of meter: pincers type
Measurement: 4-20mA current loop
Measuring instrument features: 0-24mA direct current source and simulation mode; automatic power-off; direct current loop 24 V supply option; HOLD function
Dimensions: 246x70x44mm
Power supply: battery LR6 AA 1,5V x4
Operating temperature: -10...50°C
Kind of display used: LCD
Signal measurements: 0-20,99mA (0,01mA resolution, accuracy: 0,2% + 5 digits); 21-100mA (0,1mA resolution, accuracy: 1% + 5 digits)
Alias: 3362352
Illumination: yes
Additional functions: torch
IP rating: IP40
Produkt ist nicht verfügbar
FLUKE 773 FLK-770-DTE.PDF
Hersteller: FLUKE
Category: Clamp Meters - Others
Description: Meter: current loop; pincers type; LCD; VDC: 0÷30V; IP40
Type of meter: current loop
Kind of display used: LCD
DC voltage measuring range: 0...30V
Measurement: 4-20mA current loop; DC voltage
Measuring instrument features: 0-24mA direct current source and simulation mode; automatic power-off; direct current loop 24 V supply option; HOLD function; scaled output signal mA; simultaneous measurement of current intensity (mA) and source mode (mA); type of 0-10 V source of direct current
IP rating: IP40
Operating temperature: -10...50°C
Power supply: battery LR6 AA 1,5V x4
Dimensions: 246x70x44mm
Kind of meter: pincers type
Illumination: yes
Additional functions: torch
Signal measurements: 0-20,99mA (0,01mA resolution, accuracy: 0,2% + 5 digits); 21-100mA (0,1mA resolution, accuracy: 1% + 5 digits)
auf Bestellung 7 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+2028.31 EUR
FLUKE-1773 flk-210548-en-1770-series-ds-w.pdf?_QKpV7UdY52BPvb.mUS9MzVGDY74jSlr
Hersteller: FLUKE
Category: Power Quality Analyzers
Description: Meter: power quality logger; Network: three-phase; 280x190x62mm
Type of meter: power quality logger
Kind of network: three-phase
Measurement: AC current; active electric energy; active power; AC voltage; apparent electric energy; apparent power; DC current; DC voltage; frequency; harmonics; inrush current; reactive electric energy; reactive power
Interface: Bluetooth (option); Ethernet; USB; WiFi (option)
Manufacturer series: FLK-1770
Power supply: rechargeable battery Li-Ion x1
Measuring instrument features: built- in report generator; memory built-in; transfer measurement data wireless
Standard equipment: adapter for main socket FLK-174X-MA-C8; cable markers; crocodile clip, black FLK-AC285 x4; crocodile clip, green FLK-AC285; FLK-i17XX-FLEX1500 - current clamp x4; manufacturer's calibration certificate; test lead; test lead 3-phase + N; test leads set FLK-17XX 0,18M
IP rating: IP50
Operating temperature: -10...50°C
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Dimensions: 280x190x62mm
Weight with battery: 2.1kg
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Software: Fluke Energy Analyze Plus
Produkt ist nicht verfügbar
FLUKE-1775 flk-210548-en-1770-series-ds-w.pdf?_QKpV7UdY52BPvb.mUS9MzVGDY74jSlr
Hersteller: FLUKE
Category: Power Quality Analyzers
Description: Meter: power quality logger; Network: three-phase; 280x190x62mm
Type of meter: power quality logger
Kind of network: three-phase
Measurement: AC current; active electric energy; active power; AC voltage; apparent electric energy; apparent power; DC current; DC voltage; frequency; harmonics; inrush current; reactive electric energy; reactive power; transients
Interface: Bluetooth; Ethernet; USB; WiFi
Manufacturer series: FLK-1770
Power supply: rechargeable battery Li-Ion x1
Measuring instrument features: built- in report generator; memory built-in; transfer measurement data wireless
Standard equipment: adapter for main socket FLK-174X-MA-C8; cable markers; case; crocodile clip, black FLK-AC285 x4; crocodile clip, green FLK-AC285; FLK-i17XX-FLEX1500 - current clamp x4; magnetic hanging strap; manufacturer's calibration certificate; MP1 magnet probe (3 red and 1 black); test lead; test lead 3-phase + N; test leads set FLK-17XX 0,18M; WiFi and Bluetooth module
IP rating: IP50
Operating temperature: -10...50°C
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Dimensions: 280x190x62mm
Weight with battery: 2.1kg
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Software: Fluke Energy Analyze Plus
Produkt ist nicht verfügbar
FLUKE-1777 flk-210548-en-1770-series-ds-w.pdf?_QKpV7UdY52BPvb.mUS9MzVGDY74jSlr
Hersteller: FLUKE
Category: Power Quality Analyzers
Description: Meter: power quality logger; Network: three-phase; 280x190x62mm
Type of meter: power quality logger
Kind of network: three-phase
Measurement: AC current; active electric energy; active power; AC voltage; apparent electric energy; apparent power; DC current; DC voltage; frequency; harmonics; inrush current; reactive electric energy; reactive power; transients
Interface: Bluetooth; Ethernet; USB; WiFi
Manufacturer series: FLK-1770
Power supply: rechargeable battery Li-Ion x1
Measuring instrument features: built- in report generator; memory built-in; transfer measurement data wireless
Standard equipment: adapter for main socket FLK-174X-MA-C8; cable markers; crocodile clip, black FLK-AC285 x4; crocodile clip, green FLK-AC285; FLK-i17XX-FLEX1500 - current clamp x4; hard case; magnetic hanging strap; manufacturer's calibration certificate; MP1 magnet probe (3 red and 1 black); test lead; test lead 3-phase + N; test leads set FLK-17XX 0,18M; WiFi and Bluetooth module
IP rating: IP50
Operating temperature: -10...50°C
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Dimensions: 280x190x62mm
Weight with battery: 2.1kg
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Software: Fluke Energy Analyze Plus
Produkt ist nicht verfügbar
FLUKE 1577 10923-eng.pdf 15x7____umeng0200.pdf 15x7____umger0200.pdf
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Illumination: yes
Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test
Type of meter: digital multimeter
Weight with battery: 550g
Optional equipment: FLK-C25 soft cover
Continuity test: acoustic indication; <25Ω
True effective value measurement: True RMS AC
Measurement: AC current; AC voltage; DC current; DC voltage; insulation resistance; resistance
Dimensions (W x H x D): 100x203x50mm
Test voltage: 500V; 1kV
AC current measuring range: 10µA...60mA; 400mA
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 10µA...60mA; 400mA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ
Display parameters: (6000)
AC current measuring accuracy: ±(2% + 2 digit)
DC voltage measuring accuracy: ±(0.2% + 2 digit)
DC current measuring accuracy: ±(1% + 2 digit)
AC voltage measuring accuracy: ±(2% + 3 digit)
Resistance measuring accuracy: ±(1.2%+2 digit)
Insulation resistance measuring accuracy: ±(2% + 5digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x4
IP rating: IP40
Produkt ist nicht verfügbar
FLUKE 377 FC FLK-377FC_378FC_EN.pdf
Hersteller: FLUKE
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Interface: Bluetooth
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x2
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Software: Fluke Connect
True effective value measurement: True RMS
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; inrush current; resistance
Kind of meter: digital; pincers type
AC current measuring range: 100mA...999.9A
Resistance measuring range: 600Ω; 6kΩ; 60kΩ
DC current measuring range: 100mA...999.9A
DC voltage measuring range: 600V; 1kV
AC voltage measuring range: 600V; 1kV
Frequency measuring range: 5...500Hz
Capacitance measuring range: 0.1...100µF; 1mF
CF crest factor: 1.42 @ 1kA; 2.5 @ 600A; 3 @ 500A
Frequency measuring accuracy: ±(0.5%+5 digit)
Capacitance measuring accuracy: ±(1%+ 4 digit)
AC current measuring accuracy: ±(2% + 5 digit)
DC voltage measuring accuracy: ±(1% + 5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
AC voltage measuring accuracy: ±(1.5% + 5 digit)
Resistance measuring accuracy: ±(1%+5 digit)
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Illumination: yes
Dimensions: 274x86x47mm
Standard equipment: case; crocodile clip FLK-AC285; FLK-I2500-18 flexible current probe; magnetic hanging strap FLK-TOOLPAK; test leads FLK-TL-224; test probes TP175
Measuring instrument features: automatic power-off; contactless voltage measurement; flexible current probe up to 2500A; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; transfer measurement data wireless
Type of meter: multifunction
Weight with battery: 463g
Test: diodes
Continuity test: acoustic indication; <30Ω
Pollution degree: 2
Max. diameter of measured cable: 34mm
auf Bestellung 8 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+880.38 EUR
FLUKE-1773/BASIC
Hersteller: FLUKE
Category: Power Quality Analyzers
Description: Meter: power quality logger; Network: three-phase; 280x190x62mm
Dimensions: 280x190x62mm
Interface: Bluetooth (option); Ethernet; USB; WiFi (option)
Manufacturer series: FLK-1770
Operating temperature: -10...50°C
Standard equipment: adapter for main socket FLK-174X-MA-C8; cable markers; crocodile clip, black FLK-AC285 x4; crocodile clip, green FLK-AC285; manufacturer's calibration certificate; test lead; test lead 3-phase + N; test leads set FLK-17XX 0,18M
Measuring instrument features: built- in report generator; memory built-in; transfer measurement data wireless
Type of meter: power quality logger
Weight with battery: 2.1kg
Measurement: AC current; active electric energy; active power; AC voltage; apparent electric energy; apparent power; DC current; DC voltage; frequency; harmonics; inrush current; reactive electric energy; reactive power
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Software: Fluke Energy Analyze Plus
Power supply: rechargeable battery Li-Ion x1
IP rating: IP50
Kind of network: three-phase
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Produkt ist nicht verfügbar
FLUKE-1775/BASIC
Hersteller: FLUKE
Category: Power Quality Analyzers
Description: Meter: power quality logger; Network: three-phase; 280x190x62mm
Dimensions: 280x190x62mm
Interface: Bluetooth; Ethernet; USB; WiFi
Manufacturer series: FLK-1770
Operating temperature: -10...50°C
Standard equipment: adapter for main socket FLK-174X-MA-C8; cable markers; case; crocodile clip, black FLK-AC285 x4; crocodile clip, green FLK-AC285; manufacturer's calibration certificate; test lead; test lead 3-phase + N; test leads set FLK-17XX 0,18M
Measuring instrument features: built- in report generator; memory built-in; transfer measurement data wireless
Type of meter: power quality logger
Weight with battery: 2.1kg
Measurement: AC current; active electric energy; active power; AC voltage; apparent electric energy; apparent power; DC current; DC voltage; frequency; harmonics; inrush current; reactive electric energy; reactive power; transients
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Software: Fluke Energy Analyze Plus
Power supply: rechargeable battery Li-Ion x1
IP rating: IP50
Kind of network: three-phase
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Produkt ist nicht verfügbar
FLUKE-1777/BASIC
Hersteller: FLUKE
Category: Power Quality Analyzers
Description: Meter: power quality logger; Network: three-phase; 280x190x62mm
Dimensions: 280x190x62mm
Interface: Bluetooth; Ethernet; USB; WiFi
Manufacturer series: FLK-1770
Operating temperature: -10...50°C
Standard equipment: adapter for main socket FLK-174X-MA-C8; cable markers; crocodile clip, black FLK-AC285 x4; crocodile clip, green FLK-AC285; hard case; manufacturer's calibration certificate; test lead; test lead 3-phase + N; test leads set FLK-17XX 0,18M
Measuring instrument features: built- in report generator; memory built-in; transfer measurement data wireless
Type of meter: power quality logger
Weight with battery: 2.1kg
Measurement: AC current; active electric energy; active power; AC voltage; apparent electric energy; apparent power; DC current; DC voltage; frequency; harmonics; inrush current; reactive electric energy; reactive power; transients
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Software: Fluke Energy Analyze Plus
Power supply: rechargeable battery Li-Ion x1
IP rating: IP50
Kind of network: three-phase
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Produkt ist nicht verfügbar
77-4/EUR FLK-77-IV.pdf 77iv____umeng0000.pdf 77iv____umger0000.pdf
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.32x/s
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Continuity test: acoustic indication; <25Ω
Bargraph: 33 segm. 32x/s
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Dimensions (W x H x D): 90x185x43mm
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 1mV...6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1mA @2.4V
Battery/ rechargeable battery: battery 6LR61 9V x1
Display parameters: (6000)
Frequency measuring accuracy: ±(0.1%+1 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
AC current measuring accuracy: ±(2% + 2 digit)
DC voltage measuring accuracy: ±(0.3% + 1 digit)
DC current measuring accuracy: ±(1.5% + 2 digit)
AC voltage measuring accuracy: ±(2% + 2 digit)
Resistance measuring accuracy: ±(0.5%+1 digit)
Kind of display used: LCD
Power supply: battery 6LR61 9V x1
Standard equipment: test leads; user's manual
Measuring instrument features: auto and manual ranging; automatic power-off; HOLD function; MIN/MAX/MEDIUM function
Type of meter: digital multimeter
auf Bestellung 3 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+817.86 EUR
2824477
Hersteller: FLUKE
Category: Accessories - Others
Description: Battery container
Related items: FLK-289
Type of test accessories: battery container
auf Bestellung 3 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+109.14 EUR
3114277
Hersteller: FLUKE
Category: Accessories for Oscilloscopes - Others
Description: Rechargeable battery; FLK-1760
Type of test accessories: rechargeable battery
Related items: FLK-1760
Produkt ist nicht verfügbar
Fluke C101
Fluke C101
Hersteller: FLUKE
Category: Bags & Soft Cases
Description: Hard carrying case; FLK-1503,FLK-1507,FLK-1577,FLK-1587
Type of test accessories: hard carrying case
Related items: FLK-1503; FLK-1507; FLK-1577; FLK-1587
Dimensions: 305x360x105mm
Produkt ist nicht verfügbar
FLUKE 1560856
FLUKE 1560856
Hersteller: FLUKE
Category: Accessories - Others
Description: Display; FLK-177EGFID
Related items: FLK-177EGFID
Type of test accessories: display
auf Bestellung 4 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
3+29.99 EUR
Mindestbestellmenge: 3
FLUKE 3000FC/EDA2
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; POM-5677B,POM-5899A,POM-7519A
Type of meter: digital multimeter
Standard equipment: FLK-3000FC wireless multimeter; FLK-C35 soft cover; manual (CD); test leads FLK-TL-224; test probes FLK-AC280 SureGrip; test probes FLK-TL910
Related items: POM-5677B; POM-5899A; POM-7519A
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+708.18 EUR
FLUKE 179/EDA2/EUR Fluke 175 177 179 Datasheet EN.pdf 175_____umeng0100.pdf Fluke 175 177 179 Manual EN.pdf 175_____umger0100.pdf Fluke 175 177 179 Manual DE.pdf
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; POM-5904A/POM,POM-6343,POM-7519A
Related items: POM-5904A/POM; POM-6343; POM-7519A
Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type temperature probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; set of test leads with probes FLK-TL910; test leads FLK-TL224 SureGrip; test probes FLK-AC280 SureGrip
Battery/ rechargeable battery: battery 6LR61 9V x1
Type of meter: digital multimeter
auf Bestellung 12 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+687.63 EUR
FLUKE 179 MAG KIT 175_____umeng0100.pdf 175_____umger0100.pdf
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; POM-5904A/POM,POM-6343,POM-7519A
Related items: POM-5904A/POM; POM-6343; POM-7519A
Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type temperature probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; mini torch; test leads FLK-TL224 SureGrip; test probes FLK-AC220 SureGrip; test probes FLK-TP4
Battery/ rechargeable battery: battery 6F22 9V x1
Type of meter: digital multimeter
auf Bestellung 35 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+595.61 EUR
FLUKE 179EGFID/C11XT
FLUKE 179EGFID/C11XT
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Power supply: battery 6LR61 9V x1
Battery/ rechargeable battery: battery 6LR61 9V x1
Manufacturer series: Fluke 170
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5904A/POM; POM-6343; POM-7519A
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
Frequency measuring accuracy: ±(0,1% + 1 digits)
Resistance measuring accuracy: ±(0,9% + 1 digit)
Standard equipment: FLK-80BK-A drop-like K-type temperature probe; FLK-TL75 test leads
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; EVA-C11XT hard case; FLK-C90 soft cover; FLK-TLK220 set
DC current measuring accuracy: ±(1% + 3 digits)
Kind of display used: LCD
Temperature measuring range: -40...400°C
Continuity test: acoustic indication; <25Ω
True effective value measurement: True RMS AC
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Weight with battery: 420g
Diode test: 1.1mA @2.4V
DC voltage measuring accuracy: ±(0,09% + 2 digits)
Bargraph: 33 segm. 40x/s
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC current measuring accuracy: ±(1,5% + 3 digits)
Temperature measurement accuracy: ±(1% + 10 digits)
Alias: 5575193
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Dimensions (W x H x D): 89x190x45mm
Type of meter: digital multimeter
AC voltage measuring accuracy: ±(1% + 3 digits)
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Display parameters: 3,75 digit (6000)
Capacitance measuring accuracy: ±(1,2% + 2 digits)
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+648.72 EUR
FLUKE-9040EUR 11078-eng.pdf
Hersteller: FLUKE
Category: Phase Sequence Indicators
Description: Tester: phase sequence; LCD; Freq: 15÷400Hz; IP40
Operating frequency: 15...400Hz
Type of tester: phase sequence
Related items: FLK-BP291; FLK-C25; FLK-TLK290; FLK-TLK291
Standard equipment: 3 crocodile clips; test leads ( 3pcs.)
Weight with battery: 200g
Pollution degree: 2
Phase-to-phase voltage range for phase sequence indication: 40...700V AC
IP rating: IP40
Power supply: from tested wiring system
Measurement: motor's rotation direction; phase sequence
Kind of display used: LCD
Body dimensions: 124x61x27mm
Conform to the norm: CAT III 600V; CAT IV 300V; EN 61010
auf Bestellung 11 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+358.62 EUR
FLUKE 9062 11078-eng.pdf 9062____umeng0000.pdf 9062____umger0000.pdf
FLUKE 9062
Hersteller: FLUKE
Category: Phase Sequence Indicators
Description: Tester: phase sequence; LED; 120÷400VAC; Freq: 2÷400Hz; IP40
Operating frequency: 2...400Hz
Type of tester: phase sequence
Related items: FLK-C25; FLK-TLK290; FLK-TLK291
Standard equipment: 3 crocodile clips; test leads ( 3pcs.)
Measuring instrument features: non-contact determination of rotation field direction; voltage indicator individual for each phase
Weight with battery: 150g
Pollution degree: 2
Phase-to-phase voltage range for phase sequence indication: 120...400V AC; 1...400V AC
IP rating: IP40
Power supply: battery 6LR61 9V x1
Measurement: motor's rotation direction; phase sequence
Kind of display used: LED
Body dimensions: 124x61x27mm
Battery/ rechargeable battery: battery 6LR61 9V x1
Conform to the norm: CAT III 300V; EN 61010
auf Bestellung 4 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+329.1 EUR
FLUKE T110 Fluke T110 Datasheet (EN).pdf FLK-T90-DTE.pdf Fluke T110 Datasheet (DE).pdf Fluke T110 Manual (EN).pdf Fluke T110 Manual (DE).pdf
FLUKE T110
Hersteller: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; 12÷690VAC; 0÷400Hz; IP64; 0Ω÷400kΩ
Type of tester: electrical
Kind of display used: LEDs
Measurement: AC voltage; DC voltage
Phase-to-phase voltage range for phase sequence indication: 12...690V AC
AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring accuracy: ±(3% + 5 digit)
Bandwidth for AC voltage measurements: 0...400Hz
DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
DC voltage measuring accuracy: ±(3% + 5 digit)
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Additional functions: illumination lamp
IP rating: IP64
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Power supply: battery LR03 AAA 1,5V x2
Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button
Body dimensions: 255x78x35mm
Weight with battery: 270g
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
auf Bestellung 30 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+135.64 EUR
FLUKE T110/VDE Fluke T110 Datasheet (EN).pdf FLK-T90-DTE.pdf Fluke T110 Datasheet (DE).pdf T110vde_iseng0000.pdf Fluke T110 Manual (EN).pdf Fluke T110 Manual (DE).pdf T110vde_isger0000.pdf
FLUKE T110/VDE
Hersteller: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; 100÷690VAC; 0÷400Hz; IP64; 0Ω÷400kΩ
Type of tester: electrical
Kind of display used: LEDs
Measurement: AC voltage; DC voltage
Phase-to-phase voltage range for phase sequence indication: 100...690V AC
AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring accuracy: ±(3% + 5 digit)
Bandwidth for AC voltage measurements: 0...400Hz
DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
DC voltage measuring accuracy: ±(3% + 5 digit)
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Additional functions: illumination lamp
IP rating: IP64
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Power supply: battery LR03 AAA 1,5V x2
Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button
Body dimensions: 255x78x35mm
Weight with battery: 270g
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
auf Bestellung 11 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+131.19 EUR
FLUKE T90 FLK-T90-DTE.pdf
Hersteller: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; 12÷690VAC; 0÷400Hz; IP54; 0Ω÷400kΩ
IP rating: IP54
Body dimensions: 245x64x28mm
Additional functions: illumination lamp
Conform to the norm: CAT II 690V; CAT III 600V; EN 61010
Type of tester: electrical
Power supply: battery LR03 AAA 1,5V x2
Kind of display used: LEDs
Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; polarity identification; polarization indicator
Weight with battery: 180g
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Phase-to-phase voltage range for phase sequence indication: 12...690V AC
Measurement: AC voltage; DC voltage
Bandwidth for AC voltage measurements: 0...400Hz
DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
auf Bestellung 20 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+93.77 EUR
FLUKE 1630-2
FLUKE 1630-2
Hersteller: FLUKE
Category: Clamp Meters - Others
Description: Meter: grounding resistance; pincers type; LCD; (9999)
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+2245.1 EUR
FLUKE T130 Fluke T130 Datasheet (EN).pdf FLK-T90-DTE.pdf Fluke T130 Datasheet (DE).pdf Fluke T130 Manual (EN).pdf Fluke T130 Manual (DE).pdf
FLUKE T130
Hersteller: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 6÷690VAC; 0÷400Hz; IP64
Type of tester: electrical
Kind of display used: LCD; LEDs
Display parameters: 3,5 digit
Measurement: AC voltage; DC voltage
Phase-to-phase voltage range for phase sequence indication: 6...690V AC
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring accuracy: ±(3% + 5 digit)
Bandwidth for AC voltage measurements: 0...400Hz
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
DC voltage measuring accuracy: ±(3% + 5 digit)
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Additional functions: illumination lamp
IP rating: IP64
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Power supply: battery LR03 AAA 1,5V x2
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button
Body dimensions: 255x78x35mm
Weight with battery: 270g
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
auf Bestellung 42 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+197.37 EUR
FLUKE T130/VDE FLK-T90-DTE.pdf T110vde_iseng0000.pdf T110vde_isger0000.pdf
FLUKE T130/VDE
Hersteller: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 100÷690VAC; 0÷400Hz; IP64
Type of tester: electrical
Kind of display used: LCD; LEDs
Display parameters: 3,5 digit
Measurement: AC voltage; DC voltage
Phase-to-phase voltage range for phase sequence indication: 100...690V AC
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring accuracy: ±(3% + 5 digit)
Bandwidth for AC voltage measurements: 0...400Hz
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
DC voltage measuring accuracy: ±(3% + 5 digit)
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Additional functions: illumination lamp
IP rating: IP64
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Power supply: battery LR03 AAA 1,5V x2
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button
Body dimensions: 255x78x35mm
Weight with battery: 270g
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
auf Bestellung 11 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+198.34 EUR
FLUKE T150 FLK-T90-DTE.pdf Fluke T150 Datasheet (EN).pdf Fluke T150 Datasheet (DE).pdf Fluke T150 Manual (EN).pdf Fluke T150 Manual (DE).pdf
FLUKE T150
Hersteller: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 6÷690VAC; 0÷400Hz; IP64
Type of tester: electrical
Kind of display used: LCD; LEDs
Display parameters: 3,5 digit
Measurement: AC voltage; DC voltage; resistance
Phase-to-phase voltage range for phase sequence indication: 6...690V AC
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring accuracy: ±(3% + 5 digit)
Bandwidth for AC voltage measurements: 0...400Hz
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
DC voltage measuring accuracy: ±(3% + 5 digit)
Resistance measuring range: 1...1999Ω
Resistance measuring accuracy: ±(5%+10 digit)
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Additional functions: illumination lamp
IP rating: IP64
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Power supply: battery LR03 AAA 1,5V x2
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button
Body dimensions: 255x78x35mm
Weight with battery: 270g
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
auf Bestellung 40 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+223.94 EUR
FLUKE T150/VDE Fluke T150 Datasheet (EN).pdf FLK-T90-DTE.pdf Fluke T150 Datasheet (DE).pdf T110vde_iseng0000.pdf Fluke T150 Manual (EN).pdf Fluke T150 Manual (DE).pdf T110vde_isger0000.pdf
FLUKE T150/VDE
Hersteller: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 100÷690VAC; 0÷400Hz; IP64
Type of tester: electrical
Kind of display used: LCD; LEDs
Display parameters: 3,5 digit
Measurement: AC voltage; DC voltage; resistance
Phase-to-phase voltage range for phase sequence indication: 100...690V AC
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring accuracy: ±(3% + 5 digit)
Bandwidth for AC voltage measurements: 0...400Hz
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
DC voltage measuring accuracy: ±(3% + 5 digit)
Resistance measuring range: 1...1999Ω
Resistance measuring accuracy: ±(5%+10 digit)
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Additional functions: illumination lamp
IP rating: IP64
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Power supply: battery LR03 AAA 1,5V x2
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button
Body dimensions: 255x78x35mm
Weight with battery: 270g
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
auf Bestellung 27 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+229.59 EUR
FLUKE 1630-2 FC 1630-2-FC.pdf FLK-1630-2-INS.pdf Fluke 1630-2 FC Manual EN.pdf Fluke 1630-2 FC Manual DE.pdf
Hersteller: FLUKE
Category: Clamp Meters - Others
Description: Meter: grounding resistance; pincers type; LCD; (9999)
Type of meter: grounding resistance
Kind of meter: pincers type
Kind of display used: LCD
Display parameters: (9999)
Measurement: leakage current; resistance
Interface: Bluetooth
Battery/ rechargeable battery: battery 6LR61 9V x1
Alias: 4829532
Resistance measuring range: 25mΩ; 250mΩ; 10Ω; 100Ω; 200Ω; 0.4kΩ; 600Ω; 1.5kΩ
Resistance measuring accuracy: ±(1,5% + 3 digits)
Continuity test: acoustic indication
auf Bestellung 5 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+2380.92 EUR
FLUKE 787B FLK-787B.pdf FLK-787B-INS.pdf
Hersteller: FLUKE
Category: Calibrators
Description: Meter: multimeter calibrator; Diode test: 0.3mA@600mV
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010; EN 61243-3:2010
Standard equipment: crocodile clips FLK-AC72; test leads FLK-TL71
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; crocodile clip FLK-AC89; crocodile clip FLK-AC220; crocodile clip FLK-AC283; crocodile clip FLK-AC285; FLK-C510 - soft cover; FLK-FVF-SC2 software; FLK-TL225 set
Related items: POM-5900A/POM; POM-6173A; POM-7519A
Dimensions: 203x100x50mm
Measuring instrument features: automatic and manual setting of step function; HOLD function; MIN/MAX/MEAN/REL function; simultaneous readout in mA and % of range; source DC current / calibrate loop current, source/simulate
Type of meter: multimeter calibrator
Continuity test: acoustic indication; <100Ω
AC current measuring range: 0.001mA...1A
Resistance measuring range: 100mΩ...400Ω; 4kΩ; 400kΩ; 4MΩ; 40MΩ
DC current measuring range: 1µA...30mA; 1A
DC voltage measuring range: 1...400mV; 4V; 40V; 400V; 1kV
AC voltage measuring range: 0.1...400mV; 4V; 40V; 400V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.99kHz
Diode test: 0.3mA @600mV
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Software: Fluke Connect (FLK-IR3000FC)
Frequency measuring accuracy: ±(0.005%+1 digit)
AC current measuring accuracy: ±(1% + 2 digit)
DC voltage measuring accuracy: ±(0.1% + 1 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(0.7% + 2 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x4
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+1881.98 EUR
FLUKE 789 Fluke 789 Datasheet (EN).pdf 10591-eng.pdf 6001874B-EN-FC-Reasons-Why-Flyer-w.pdf 6001874B-de-FC-Reasons-Why-Flyer-w.pdf Fluke 789 Datasheet (DE).pdf Fluke 789 Manual (EN).pdf Fluke 789 Manual (DE).pdf
Hersteller: FLUKE
Category: Calibrators
Description: Meter: multimeter calibrator; Diode test: 0.3mA@600mV
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010; EN 61243-3:2010
Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; crocodile clip FLK-AC89; crocodile clip FLK-AC220; crocodile clip FLK-AC283; crocodile clip FLK-AC285; FLK-C510 - soft cover; FLK-FVF-SC2 software; FLK-TL225 set
Related items: POM-5900A/POM; POM-6173A; POM-7519A
Interface: IrDA
Dimensions: 203x100x50mm
Measuring instrument features: 0% or 100% of signal value (4mA, 20mA) source function; 24V loop supply voltage; automatic and manual setting of step function; HART range with loop and built-in 250Ω resistor; HOLD function; impact resistant holster; MIN/MAX/MEAN/REL function; simultaneous readout in mA and % of range; source DC current / calibrate loop current, source/simulate
Type of meter: multimeter calibrator
Power supply: battery LR6 AA 1,5V x4
Continuity test: acoustic indication; <100Ω
Kind of display used: LCD
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; resistance
AC current measuring range: 0.001mA...1A
Resistance measuring range: 100mΩ...400Ω; 4kΩ; 400kΩ; 4MΩ; 40MΩ
DC current measuring range: 1µA...30mA; 1A
DC voltage measuring range: 1...400mV; 4V; 40V; 400V; 1kV
AC voltage measuring range: 0.1...400mV; 4V; 40V; 400V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.99kHz
Diode test: 0.3mA @600mV
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Software: Fluke Connect (FLK-IR3000FC)
Frequency measuring accuracy: ±(0.005%+1 digit)
AC current measuring accuracy: ±(1% + 2 digit)
DC voltage measuring accuracy: ±(0.1% + 1 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1.2% + 4 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+2154.47 EUR
FLUKE-110/ERTA FLK-110_EN.pdf
FLUKE-110/ERTA
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.32x/s
Type of meter: digital multimeter
Measurement: AC voltage; continuity; DC voltage; resistance
Kind of display used: LCD
Display parameters: (6000)
Bargraph: 33 segm. 32x/s
DC voltage measuring range: 600mV; 6V; 60V; 600V
DC voltage measuring accuracy: ±(0.5% + 2 digit)
AC voltage measuring range: 600mV; 6V; 60V; 600V
AC voltage measuring accuracy: ±(1% + 3 digit)
True effective value measurement: True RMS AC
Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
Resistance measuring accuracy: ±(0.9%+1 digit)
Continuity test: acoustic indication; <20Ω
Pollution degree: 2
Weight with battery: 350g
Power supply: battery 6F22 9V x1
Standard equipment: test leads TL75
Conform to the norm: CAT III 600V; EN 61010
Dimensions (W x H x D): 96x160x46mm
Measuring instrument features: MIN/MAX/MEDIUM function; pocket size
Battery/ rechargeable battery: battery 6F22 9V x1
Manufacturer series: Fluke 110
Illumination: yes
auf Bestellung 20 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+201.66 EUR
FLUKE 88V/A FLK-88V-A.PDF 88v_____umeng0100.pdf 88v_____umger0100.pdf
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; VDC: 0÷1kV; VAC: 0÷1kV; I DC: 0÷10A; 0÷50MΩ
Type of meter: digital multimeter
Kind of display used: LCD
Bargraph: yes
DC current measuring range: 0...10A
AC current measuring range: 0...10A
Measuring instrument features: auto and manual ranging; HOLD function; MIN/MAX/MEAN/REL function; PEAK HOLD function; settable MIN/MAX alarm thresholds
DC voltage measuring range: 0...1kV
AC voltage measuring range: 0...1kV
True effective value measurement: True RMS AC
Resistance measuring range: 0...50MΩ
Capacitance measuring range: 0...10000µF
Frequency measuring range: 0...200kHz
Temperature measuring range: -200...1090°C
Continuity test: acoustic indication
Diode test: 3V
Standard equipment: automotive back probe pins 2pcs; crocodile clips FLK-AC285; FLK-80BK-A drop-like K-type temperature probe; hard case FLK-800; holster; insulation piercing clip; magnetic hanging strap FLK-TOOLPAK; probe FLK-RPM80; test leads FLK-TL224 SureGrip; test probes FLK-TP220
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Battery/ rechargeable battery: battery 6F22 9V x1
Dimensions (W x H x D): 86x186x32mm
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+1246.83 EUR
FLUKE 279FC/IFLEX Fluke 279 FC Datasheet (EN).pdf Fluke 279 FC Datasheet (DE).pdf Fluke 279 FC Manual (EN).pdf Fluke 279 FC Manual (DE).pdf
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter with infrared camera; Bluetooth; Plug: EU
Type of meter: digital multimeter with infrared camera
Interface: Bluetooth
Measurement: AC current; AC voltage; capacitance; DC voltage; frequency; non-contact temeprature (IR); resistance
DC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
AC current measuring range: 100mA...999.9A; 2.5kA
Resistance measuring range: 600Ω...50MΩ
Capacitance measuring range: 1000nF...9999µF
Frequency measuring range: 99.99...999.9Hz
Non-contact temperature measuring range: -10...200°C
Diode test: 2V
Continuity test: acoustic indication; <25Ω
Standard equipment: battery charger/power supply; case; FLK-I2500-18 flexible current probe; FLK-TL175 test leads
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5677B; POM-5899A; POM-7519A
Plug variant: EU
Refresh rate: 8Hz
Emissivity value: 0,95 (fixed)
Focusing: focus free
Dimensions (W x H x D): 93.9x215.9x57.1mm
Camera resolution: 80x60
Thermal sensitivity (NETD): ≤0.2°C
Battery/ rechargeable battery: rechargeable battery Li-Ion 7,4V 3000mAh x1
Connectors for the country: Great Britain
auf Bestellung 3 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+1679.76 EUR
FLUKE 3000 FC FLK-3000FC-DTE.pdf 6001874B-EN-FC-Reasons-Why-Flyer-w.pdf 6001874B-de-FC-Reasons-Why-Flyer-w.pdf FLK-3000FC-INS.pdf
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; Bluetooth; LCD; VDC: 600mV,6V,60V,600V,1kV
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Continuity test: acoustic indication
True effective value measurement: True RMS
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Dimensions (W x H x D): 93x207x48mm
AC current measuring range: 60mA; 400mA
Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 60mA; 400mA
DC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 9.999Hz; 99.99Hz; 999.9Hz; 99.99kHz
Capacitance measuring range: 1µF; 10µF; 100µF; 9.999mF
Diode test: 2V
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Software: compatible Android; Fluke Connect
Frequency measuring accuracy: ±(0.1%+1 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
DC current measuring accuracy: ±(0.5% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.5%+1 digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x3
IP rating: IP54
Interface: Bluetooth
Related items: FLK-A3001FC-KITCAR; POM-5677B; POM-5899A; POM-7519A
Standard equipment: crocodile clips FLK-AC175; FLK-TL175 test leads
Measuring instrument features: 20m range; auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function
Type of meter: digital multimeter
Weight with battery: 340g
auf Bestellung 3 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+540.97 EUR
FLUKE 1587T 15x7____umeng0200.pdf 15x7____umger0200.pdf
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Optional equipment: FLK-C25 soft cover
Continuity test: acoustic indication; <25Ω
Temperature measurement resolution: 0.1°C
Temperature measuring range: -40...537°C
True effective value measurement: True RMS
Measurement: AC current; capacitance; DC current; frequency; insulation resistance; resistance; temperature
Dimensions (W x H x D): 100x203x50mm
Test voltage: 50V; 100V
AC current measuring range: 10µA...60mA; 400mA
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 10µA...60mA; 400mA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1mA @6V
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Insulation resistance measuring ranges: 10kΩ...100MΩ
Display parameters: (6000)
Frequency measuring accuracy: ±(0.1%+1 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 2 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+2 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x4
IP rating: IP40
Illumination: yes
Standard equipment: crocodile clips FLK-AC285; FLK-80BK-A drop-like K-type temperature probe; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; for telecommunication; HOLD function; indicates incorrect connection of test leads; insulation resistance test; MIN/MAX/MEDIUM function
Type of meter: digital multimeter
auf Bestellung 4 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+1220.48 EUR
Fluke 123B Fluke 120B Series Datasheet EN.pdf Fluke 120B Series Datasheet DE.pdf FLK-123B-INS.pdf Fluke 120B Series Manual EN.pdf Fluke 120B Series Manual DE.pdf
Hersteller: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div
Kind of display used: colour; LCD TFT 5,7"
Sampling: 40Msps
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Resistance measuring accuracy: ±(0.6%+5 digit)
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Continuity test: acoustic indication
Diode test: 0.5mA @2.8V
Dimensions: 259x132x55mm
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Additional functions: multimeter
IP rating: IP51
Related items: POM-72941; POM-72942
Manufacturer series: FLUKE 120B
Band: 20MHz
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Time base: 20n...60s/div
Number of channels: 2
Type of oscilloscope: scopemeter
Plug variant: EU
Display resolution: 640x480
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+2800.96 EUR
Fluke 123B/S Fluke 120B Series Datasheet EN.pdf Fluke 120B Series Datasheet DE.pdf Fluke 120B Series Manual EN.pdf FLK-123B-INS.pdf Fluke 120B Series Manual DE.pdf
Hersteller: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div
Kind of display used: colour; LCD TFT 5,7"
Sampling: 40Msps
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Resistance measuring accuracy: ±(0.6%+5 digit)
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Continuity test: acoustic indication
Diode test: 0.5mA @2.8V
Dimensions: 259x132x55mm
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Additional functions: multimeter
IP rating: IP51
Related items: POM-72941; POM-72942
Manufacturer series: FLUKE 120B
Band: 20MHz
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Software: Fluke View
Time base: 20n...60s/div
Number of channels: 2
Type of oscilloscope: scopemeter
Plug variant: EU
Display resolution: 640x480
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+3601.68 EUR
Fluke 124B Fluke 120B Series Datasheet EN.pdf Fluke 120B Series Datasheet DE.pdf Fluke 120B Series Manual EN.pdf FLK-123B-INS.pdf Fluke 120B Series Manual DE.pdf
Hersteller: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Kind of display used: colour; LCD TFT 5,7"
Sampling: 40Msps
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Resistance measuring accuracy: ±(0.6%+5 digit)
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Continuity test: acoustic indication
Diode test: 0.5mA @2.8V
Dimensions: 259x132x55mm
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Additional functions: multimeter
IP rating: IP51
Related items: POM-72941; POM-72942
Manufacturer series: FLUKE 120B
Band: 40MHz
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Time base: 10n...60s/div
Number of channels: 2
Type of oscilloscope: scopemeter
Plug variant: EU
Display resolution: 640x480
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+3361.67 EUR
Fluke 124B/S Fluke 120B Series Datasheet EN.pdf Fluke 120B Series Datasheet DE.pdf FLK-123B-INS.pdf Fluke 120B Series Manual EN.pdf Fluke 120B Series Manual DE.pdf
Hersteller: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Kind of display used: colour; LCD TFT 5,7"
Sampling: 40Msps
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Resistance measuring accuracy: ±(0.6%+5 digit)
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Continuity test: acoustic indication
Diode test: 0.5mA @2.8V
Dimensions: 259x132x55mm
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Additional functions: multimeter
IP rating: IP51
Related items: POM-72941; POM-72942
Manufacturer series: FLUKE 120B
Band: 40MHz
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Software: Fluke View
Time base: 10n...60s/div
Number of channels: 2
Type of oscilloscope: scopemeter
Plug variant: EU
Display resolution: 640x480
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+4140.32 EUR
Fluke 125B Fluke 120B Series Datasheet EN.pdf Fluke 120B Series Datasheet DE.pdf FLK-123B-INS.pdf Fluke 120B Series Manual EN.pdf Fluke 120B Series Manual DE.pdf
Hersteller: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Kind of display used: colour; LCD TFT 5,7"
Sampling: 40Msps
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Resistance measuring accuracy: ±(0.6%+5 digit)
Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Continuity test: acoustic indication
Diode test: 0.5mA @2.8V
Dimensions: 259x132x55mm
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; FLK-I400S - current clamp
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Additional functions: multimeter
IP rating: IP51
Related items: POM-72941; POM-72942
Manufacturer series: FLUKE 120B
Band: 40MHz
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Time base: 10n...60s/div
Number of channels: 2
Type of oscilloscope: scopemeter
Plug variant: EU
Display resolution: 640x480
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+4014.22 EUR
Fluke 125B/S Fluke 120B Series Datasheet EN.pdf Fluke 120B Series Datasheet DE.pdf Fluke 120B Series Manual EN.pdf FLK-123B-INS.pdf Fluke 120B Series Manual DE.pdf
Hersteller: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Kind of display used: colour; LCD TFT 5,7"
Sampling: 40Msps
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Resistance measuring accuracy: ±(0.6%+5 digit)
Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Continuity test: acoustic indication
Diode test: 0.5mA @2.8V
Dimensions: 259x132x55mm
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; FLK-I400S - current clamp; magnetic hanging strap; screen protector
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Additional functions: multimeter
IP rating: IP51
Manufacturer series: FLUKE 120B
Band: 40MHz
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Software: Fluke View
Time base: 10n...60s/div
Number of channels: 2
Type of oscilloscope: scopemeter
Plug variant: EU
Display resolution: 640x480
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+4691.5 EUR
FLUKE 1587 FC Fluke 1587 FC Datasheet (EN).pdf Fluke 1587 FC Datasheet (DE).pdf 15x7____umeng0200.pdf Fluke 1587 FC Manual (EN).pdf 15x7____umger0200.pdf Fluke 1587 FC Manual (DE).pdf
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; Bluetooth; LCD; (6000); I DC: 0.01÷60mA,400mA
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Optional equipment: FLK-C25 soft cover
Continuity test: acoustic indication; <25Ω
Temperature measurement resolution: 0.1°C
Temperature measuring range: -40...537°C
True effective value measurement: True RMS AC
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; insulation resistance; resistance; temperature
Dimensions (W x H x D): 100x203x50mm
Test voltage: 500V
AC current measuring range: 10µA...60mA; 400mA
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 10µA...60mA; 400mA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1mA @6V
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ
Display parameters: (6000)
Frequency measuring accuracy: ±(0.1%+1 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 2 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+2 digit)
Insulation resistance measuring accuracy: ±(1.5% + 5digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x4
IP rating: IP40
Interface: Bluetooth
Illumination: yes
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5906A; POM-5907A; POM-6041B
Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test
Type of meter: digital multimeter
Weight with battery: 550g
auf Bestellung 13 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+1314.37 EUR
Fluke 373 flk-373.pdf 373_____umeng0000.pdf 373_____umger0000.pdf
Hersteller: FLUKE
Category: Meters and AC Clamp Probes
Description: Meter: multifunction; digital,pincers type; LCD; Øcable: 32mm
Type of meter: multifunction
Kind of meter: digital; pincers type
Max. diameter of measured cable: 32mm
Kind of display used: LCD
AC current measuring range: 100mA...600A
Measuring instrument features: automatic power-off; HOLD function
AC current measuring accuracy: ±(2% + 5 digit)
DC voltage measuring range: 100mV...600V
DC voltage measuring accuracy: ±(1% + 5 digit)
AC voltage measuring range: 100mV...600V
AC voltage measuring accuracy: ±(1% + 5 digit)
Resistance measuring accuracy: ±(1%+5 digit)
True effective value measurement: True RMS
Resistance measuring range: 100mΩ...600Ω; 6kΩ
Capacitance measuring range: 0.1...10µF; 100µF; 1mF
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
Continuity test: acoustic indication; <30Ω
Pollution degree: 2
Body dimensions: 232x85x45mm
Weight without batteries: 370g
Power supply: battery LR6 AA 1,5V x2
Standard equipment: case; test leads
Optional equipment: crocodile clip FLK-AC89; crocodile clip FLK-AC220; FLK-TL175 test leads; FLK-TL220 set; test leads FLK-TL75
Measurement: AC current; AC voltage; capacitance; DC voltage; resistance
Conform to the norm: CAT III 600V; CAT IV 300V; EN 61010
Related items: POM-5913; POM-6173A; POM-7519A
Illumination: yes
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+460.53 EUR
FLUKE 355 FLK-353-FLK-355.PDF 353_355_umeng0000.pdf 353_355_umger0000.pdf
Hersteller: FLUKE
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 58mm; LCD
Related items: POM-5673B; POM-5907A; POM-6041B
Illumination: yes
Dimensions: 300x98x52mm
Standard equipment: crocodile clips; soft cover FLK-C43; test leads
Measuring instrument features: HOLD function; MIN/MAX, MAX-MIN, MEAN function
Type of meter: multifunction
Weight without batteries: 814g
Continuity test: acoustic indication
Max. diameter of measured cable: 58mm
True effective value measurement: True RMS
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; inrush current; resistance
Kind of meter: digital; pincers type
AC current measuring range: 40A; 400A; 2kA
Resistance measuring range: 0.4kΩ; 4kΩ; 40kΩ; 400kΩ
DC current measuring range: 40A; 400A; 2kA
DC voltage measuring range: 4V; 40V; 400V; 1kV
AC voltage measuring range: 4V; 40V; 400V; 750V; 1kV
Frequency measuring range: 5Hz; 100Hz; 1kHz
Frequency measuring accuracy: ±(0.5%+5 digit)
AC current measuring accuracy: ±(1.5% + 5 digit)
DC voltage measuring accuracy: ±(1% + 5 digit)
DC current measuring accuracy: ±(1.5% + 5 digit)
AC voltage measuring accuracy: ±(1% + 5 digit)
Resistance measuring accuracy: ±(1%+5 digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x6
auf Bestellung 3 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+1363.46 EUR
FLK-115/TLK-225-1
FLK-115/TLK-225-1
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
auf Bestellung 113 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+326.58 EUR
FLK-IB117
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Conform to the norm: CAT III 600V; EN 61010
Manufacturer series: Fluke 110
Optional equipment: FLK-80BK-A drop-like K-type temperature probe; FLK-80PJ-EXT drop-like J-type temperature probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Continuity test: acoustic indication; <20Ω
Pollution degree: 2
True effective value measurement: True RMS AC
Bargraph: 33 segm. 32x/s
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Dimensions (W x H x D): 84x167x46mm
AC current measuring range: 1mA...6A; 10A; (20A <30s)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
DC current measuring range: 1mA...6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1.2mA @2.7V
Battery/ rechargeable battery: battery 6LR61 9V x1
Display parameters: 3,75 digit (6000)
Frequency measuring accuracy: ±(0.1%+2 digit)
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring accuracy: ±(0.5% + 2 digit)
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Kind of display used: LCD
Power supply: battery 6LR61 9V x1
Standard equipment: 3x insulated screwdrivers; FLK-TL75 test leads
Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); HOLD function; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Type of meter: digital multimeter
Weight with battery: 550g
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+472.93 EUR
FLUKE 27-II FLK-27-2.pdf 2x_2____umeng0100.pdf 2x_2____umger0100.pdf
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; IP67
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Continuity test: acoustic indication
Duty cycle factor: 0...99.9%
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Temperature measurement resolution: 0.1°C
Conductance measurement: 0.01...60nS
Temperature measuring range: -200...1090°C
Bargraph: 33 segm. 40x/s
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Dimensions (W x H x D): 100x198x63.5mm
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Diode test: 1mA @2.8V
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Display parameters: (6000)
Frequency measuring accuracy: ±(0.005%+1 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 2 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(2% + 3 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x3
IP rating: IP67
Illumination: yes
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Standard equipment: test leads
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; HOLD function; MIN/MAX/MEAN/REL function; shock-resistant case
Type of meter: digital multimeter
Weight with battery: 517g
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+1035.42 EUR
FLUKE 365 Fluke 365 Datasheet EN.pdf Fluke 365 Datasheet DE.pdf Fluke 365 Manual EN.pdf Fluke 365 Manual DE.pdf
Hersteller: FLUKE
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 18mm; LCD
Type of meter: multifunction
Measurement: AC current; AC voltage; DC current; DC voltage; resistance
Max. diameter of measured cable: 18mm
Kind of display used: LCD
DC voltage measuring range: 100mV...600V
DC voltage measuring accuracy: ±(1.5% + 5 digit)
AC voltage measuring range: 100mV...600V
AC voltage measuring accuracy: ±(1% + 5 digit)
DC current measuring range: 100mA...200A
DC current measuring accuracy: ±(2% + 5 digit)
AC current measuring range: 100mA...200A
AC current measuring accuracy: ±(2% + 5 digit)
True effective value measurement: True RMS
Resistance measuring range: 100mΩ...600Ω; 6kΩ
Resistance measuring accuracy: ±(1%+5 digit)
Continuity test: acoustic indication; <30Ω
Dimensions: 225x65x46mm
Weight with battery: 275g
Power supply: battery LR6 AA 1,5V x2
Standard equipment: case; fixed test leads; FLK-TL75 test leads
Optional equipment: crocodile clip FLK-AC220; crocodile clip FLK-AC285; FLK-C43 soft cover; FLK-TL220 set; test leads FLK-TL71; test leads FLK-TL224 SureGrip
Additional functions: torch
Measuring instrument features: automatic power-off; current clamp can be detached from the meter for measurements in hard-to-reach places; LED for measurement spot illumination
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Illumination: yes
Kind of meter: digital; pincers type
auf Bestellung 5 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+462.71 EUR
FLUKE 28-II Fluke 28-II Datasheet EN.pdf Fluke 28-II Datasheet DE.pdf 2x_2____umeng0100.pdf Fluke 28-II Manual EN.pdf 2x_2____umger0100.pdf Fluke 28-II Manual DE.pdf
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; True RMS
Type of meter: digital multimeter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Kind of display used: LCD
Display parameters: (6000)
Bargraph: 33 segm. 40x/s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.05% + 1 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1% + 4 digit)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC current measuring accuracy: ±(0.2% + 2 digit)
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
AC current measuring accuracy: ±(1% + 2 digit)
True effective value measurement: True RMS
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Capacitance measuring accuracy: ±(1%+ 2 digit)
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
Temperature measuring range: -200...1090°C
Temperature measurement accuracy: ±(1% + 10 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Temperature measurement resolution: 0.1°C
Conductance measurement: 0.01...60nS
Duty cycle factor: 0...99.9%
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Diode test: 1mA @2.8V
Continuity test: acoustic indication
IP rating: IP67
Weight with battery: 517g
Power supply: battery LR6 AA 1,5V x3
Standard equipment: test leads
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Dimensions (W x H x D): 100x198x63.5mm
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Illumination: yes
auf Bestellung 4 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+1031.86 EUR
FLUKE 28 II EX Fluke 28-II Datasheet EN.pdf Fluke 28-II Datasheet DE.pdf 2x_2____umeng0100.pdf Fluke 28-II Manual EN.pdf Fluke 28-II Manual DE.pdf 2x_2____umger0100.pdf
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/19999); Bargraph: 33segm.40x/s
Type of meter: digital multimeter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Kind of display used: LCD
Display parameters: (6000/19999)
Bargraph: 33 segm. 40x/s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.05% + 1 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1% + 4 digit)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC current measuring accuracy: ±(0.2% + 2 digit)
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
AC current measuring accuracy: ±(1% + 2 digit)
True effective value measurement: True RMS
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Capacitance measuring accuracy: ±(1%+ 2 digit)
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
Temperature measuring range: -200...1090°C
Temperature measurement accuracy: ±(1% + 10 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Temperature measurement resolution: 0.1°C
Conductance measurement: 0.01...60nS
Duty cycle factor: 0...99.9%
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Diode test: 1mA @2.8V
Continuity test: acoustic indication
IP rating: IP67
Weight with battery: 517g
Power supply: battery LR03 AAA 1,5V x3
Standard equipment: test leads
Optional equipment: crocodile clip FLK-AC285; FLK-80BK-A drop-like K-type temperature probe; FLK-80PK-1 drop-like K-type temperature probe; FLK-80PK-8 drop-like K-type temperature probe; FLK-80PK-9 drop-like K-type temperature probe; FLK-80PK-27 drop-like K-type temperature probe; FLK-C101 hard case; FLK-TL175 test leads; test leads FLK-TL71
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Dimensions (W x H x D): 100x198x63.5mm
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; intrinsic safety; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case
Battery/ rechargeable battery: battery LR03 AAA 1,5V x3
Illumination: yes
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+2477.37 EUR
FLUKE 381 Fluke 381 Datasheet EN.pdf Fluke 381 Datasheet DE.pdf Fluke 381 Manual EN.pdf Fluke 381 Manual DE.pdf
Hersteller: FLUKE
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Optional equipment: FLK-TL175 test leads; FLK-TL223 accessory set
Related items: POM-5913; POM-6173A; POM-7519A
Measuring instrument features: automatic power-off; flexible current probe; HOLD function; MIN/MAX/MEDIUM function; wireless display (range up to 10m)
Type of meter: multifunction
Continuity test: acoustic indication; <30Ω
Max. diameter of measured cable: 34mm
True effective value measurement: True RMS
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; inrush current; resistance
Kind of meter: digital; pincers type
AC current measuring range: 100mA...1kA
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ
DC current measuring range: 100mA...1kA
DC voltage measuring range: 100mV...600V; 1kV
AC voltage measuring range: 100mV...600V; 1kV
Frequency measuring range: 5...500Hz
CF crest factor: 1.42 @ 1kA; 2.5 @ 600A; 3 @ 500A
Frequency measuring accuracy: ±(0.5%+5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
DC voltage measuring accuracy: ±(1.5% + 5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
AC voltage measuring accuracy: ±(1.5% + 5 digit)
Resistance measuring accuracy: ±(1%+5 digit)
Kind of display used: LCD
Power supply: battery LR03 AAA 1,5V x5
Body dimensions: 277x88x43mm
Illumination: yes
auf Bestellung 7 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+1031.37 EUR
FLUKE 393 FC FLK-393FC-EN.pdf
Hersteller: FLUKE
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Interface: Bluetooth
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x2
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Software: Fluke Connect
True effective value measurement: True RMS
Measurement: AC current; AC voltage; capacitance; continuity; current (with current clamps); DC current; DC voltage; frequency; inrush current; peak current; resistance
Kind of meter: digital; pincers type
AC current measuring range: 100mA...999.9A
Resistance measuring range: 600Ω; 6kΩ; 60kΩ
DC current measuring range: 100mA...999.9A
DC voltage measuring range: 600V; 1.5kV
AC voltage measuring range: 600V; 1kV
Frequency measuring range: 5...500Hz
Capacitance measuring range: 0.1...100µF; 1mF
CF crest factor: 1.42k @ 2.5kA; 2.5k @ 600A; 3k @ 1.1kA
Frequency measuring accuracy: ±(0.5%+5 digit)
Capacitance measuring accuracy: ±(1%+ 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
DC voltage measuring accuracy: ±(1% + 5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
AC voltage measuring accuracy: ±(1% + 5 digit)
Resistance measuring accuracy: ±(1%+5 digit)
Conform to the norm: CAT III 1500V; CAT IV 600V; EN 61010
Illumination: yes
Dimensions: 281x84x49mm
Standard equipment: case; iFlex2500-18 - current clamp; magnetic hanging strap; test leads ( 2pcs.)
Measuring instrument features: AUTO HOLD; automatic power-off; flexible current probe up to 2500A; HOLD function; MIN/MAX/AVG function; polarization indicator
Type of meter: multifunction
Weight with battery: 520g
Continuity test: acoustic indication; <30Ω
Pollution degree: 2
Max. diameter of measured cable: 34mm
auf Bestellung 9 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+963.38 EUR
FLUKE 83V Fluke 83V 87V Datasheet EN.pdf Fluke 83V 87V Datasheet DE.pdf fluke 83 V Manual (EN).pdf fluke 83 V Manual (DE).pdf
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; 0.01÷60S
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: (6000)
Bargraph: 33 segm. 40x/s
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
Measuring instrument features: auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; test leads resistance compensation
DC current measuring accuracy: ±(0.4% + 2 digit)
AC current measuring accuracy: ±(1.2% + 2 digit)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.1% + 1 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(0.7% + 4 digit)
Resistance measuring accuracy: ±(0.4%+1 digit)
True effective value measurement: True RMS AC
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Capacitance measuring accuracy: ±(1%+ 2 digit)
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
Continuity test: acoustic indication
Diode test: 1mA @3V
Pollution degree: 2
Weight with battery: 600g
Power supply: battery 6F22 9V x1
Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
IP rating: IP30
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Battery/ rechargeable battery: battery 6F22 9V x1
Illumination: yes
Conductance measuring accuracy: ±(1% + 10digit)
Dimensions (W x H x D): 95x200x48mm
Conductance measurement: 0.01...60S
auf Bestellung 6 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+828.27 EUR
FLUKE 87-V Fluke 87 V Datasheet (EN).pdf Fluke 87 V Datasheet (DE).pdf Fluke 87 V Manual (EN).pdf Fluke 87 V Manual (DE).pdf
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Standard equipment: crocodile clips FLK-AC72; FLK-80BK-A drop-like K-type temperature probe; FLK-TL175 test leads
Type of meter: digital multimeter
Weight with battery: 600g
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Continuity test: acoustic indication
Pollution degree: 2
Temperature measurement resolution: 0.1°C
Conductance measurement: 0.01...60nS
Temperature measuring range: -200...1090°C
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Dimensions (W x H x D): 95x200x48mm
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Diode test: 1mA @3V
Battery/ rechargeable battery: battery 6F22 9V x1
Display parameters: (6000/20000)
Frequency measuring accuracy: ±(0.005%+1 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
AC current measuring accuracy: ±(1% + 2 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Kind of display used: LCD
Power supply: battery 6F22 9V x1
IP rating: IP30
Illumination: yes
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
auf Bestellung 15 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+844.27 EUR
FLUKE 87-V MAX FLK-87VMAX.pdf
FLUKE 87-V MAX
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B
Standard equipment: crocodile clip FLK-AC175 x2; FLK-80BK-A drop-like K-type temperature probe; FLK-TL175 test leads
Type of meter: digital multimeter
Weight with battery: 700g
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Continuity test: acoustic indication
Pollution degree: 2
Temperature measurement resolution: 0.1°C
Conductance measurement: 0.01...60nS
Temperature measuring range: -200...1090°C
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Dimensions (W x H x D): 63x198x100mm
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Diode test: 1mA @3V
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Display parameters: (6000/20000)
Frequency measuring accuracy: ±(0.005%+1 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
AC current measuring accuracy: ±(1% + 2 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
DC current measuring accuracy: ±(0.2% + 4 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x3
IP rating: IP67
Illumination: yes
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
auf Bestellung 8 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+939.51 EUR
FLUKE-87V-MAX/E2 KIT FLK-87VMAX.pdf
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B
Standard equipment: crocodile clip FLK-AC220 x2; FLK-80BK-A drop-like K-type temperature probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; test leads FLK-TL-224; test probes FLK-TL238
Type of meter: digital multimeter
Weight with battery: 700g
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Continuity test: acoustic indication
Pollution degree: 2
Temperature measurement resolution: 0.1°C
Conductance measurement: 0.01...60nS
Temperature measuring range: -200...1090°C
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Dimensions (W x H x D): 63x198x100mm
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Diode test: 1mA @3V
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Display parameters: (6000/20000)
Frequency measuring accuracy: ±(0.005%+1 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
AC current measuring accuracy: ±(1% + 2 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
DC current measuring accuracy: ±(0.2% + 4 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x3
IP rating: IP67
Illumination: yes
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
auf Bestellung 3 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+1109.39 EUR
FLK-87VMAX-PVLEAD1
Hersteller: FLUKE
Category: PV and EVSE Testers and Meters
Description: Meter: digital multimeter; VAC accuracy: ±(0.7%+4digit); IP67
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Continuity test: acoustic indication
Temperature measurement resolution: 0.1°C
Conductance measurement: 0.01...60nS
Temperature measuring range: -200...1090°C
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Dimensions (W x H x D): 63x198x100mm
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Diode test: 1mA @3V
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Display parameters: (6000/20000)
Frequency measuring accuracy: ±(0.005%+1 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
AC current measuring accuracy: ±(1% + 2 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
DC current measuring accuracy: ±(0.2% + 4 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x3
IP rating: IP67
Illumination: yes
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B
Standard equipment: crocodile clip FLK-AC175 x2; FLK-80BK-A drop-like K-type temperature probe; FLK-TL175 test leads; test leads MC4
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
Type of meter: digital multimeter
Weight with battery: 700g
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+1063.71 EUR
FLUKE 374 FC Fluke 374 FC Datasheet (EN).pdf Fluke 374 FC Datasheet (DE).pdf Fluke 374 FC Manual (EN).pdf Fluke 374 FC Manual (DE).pdf
Hersteller: FLUKE
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Type of meter: multifunction
Kind of display used: LCD
Resistance measuring range: 100mΩ...600Ω; 6kΩ
Capacitance measuring range: 0.1...100µF; 1mF
DC voltage measuring range: 100mV...600V
DC voltage measuring accuracy: ±(1% + 5 digit)
AC voltage measuring range: 100mV...600V
AC voltage measuring accuracy: ±(1.5% + 5 digit)
Frequency measuring range: 5...500Hz
Frequency measuring accuracy: ±(0.5%+5 digit)
DC current measuring range: 100mA...600A
DC current measuring accuracy: ±(2% + 5 digit)
AC current measuring range: 100mA...600A
AC current measuring accuracy: ±(2% + 5 digit)
Capacitance measuring accuracy: ±(1%+ 4 digit)
Resistance measuring accuracy: ±(1%+5 digit)
Test: diodes
Continuity test: acoustic indication; <30Ω
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; inrush current; resistance
Interface: Bluetooth
Software: Fluke Connect
Illumination: yes
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Power supply: battery LR6 AA 1,5V x2
Dimensions: 246x83x43mm
Measuring instrument features: automatic power-off; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; transfer measurement data wireless
Optional equipment: FLK-C43 soft cover; FLK-I2500-10 flexible current probe; FLK-I2500-18 flexible current probe
Related items: POM-5913; POM-6173A; POM-7519A
Pollution degree: 2
Max. diameter of measured cable: 34mm
Weight with battery: 388g
True effective value measurement: True RMS
Kind of meter: digital; pincers type
CF crest factor: 2.5 @ 600A
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+639.21 EUR
Wählen Sie Seite:    << Vorherige Seite ]  1 8 16 24 32 40 48 56 64 72 75 76 77 78 79 80 81 82 83 84 85 87  Nächste Seite >> ]