FLUKE 789
Hersteller: FLUKE
Category: Calibrators
Description: Meter: multimeter calibrator; Diode test: 0.3mA@600mV
Related items: POM-5900A/POM; POM-6173A; POM-7519A
Dimensions: 203x100x50mm
Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads
Measuring instrument features: 0% or 100% of signal value (4mA, 20mA) source function; 24V loop supply voltage; automatic and manual setting of step function; HART range with loop and built-in 250Ω resistor; HOLD function; impact resistant holster; MIN/MAX/MEAN/REL function; simultaneous readout in mA and % of range; source DC current / calibrate loop current, source/simulate
Type of meter: multimeter calibrator
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; crocodile clip FLK-AC89; crocodile clip FLK-AC220; crocodile clip FLK-AC283; crocodile clip FLK-AC285; FLK-C510 - soft cover; FLK-FVF-SC2 software; FLK-TL225 set
Continuity test: acoustic indication; <100Ω
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; resistance
AC current measuring range: 0.001mA...1A
Resistance measuring range: 100mΩ...400Ω; 4kΩ; 400kΩ; 4MΩ; 40MΩ
DC current measuring range: 1µA...30mA; 1A
DC voltage measuring range: 1...400mV; 4V; 40V; 400V; 1kV
AC voltage measuring range: 0.1...400mV; 4V; 40V; 400V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.99kHz
Diode test: 0.3mA @600mV
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Software: Fluke Connect (FLK-IR3000FC)
Frequency measuring accuracy: ±(0.005%+1 digit)
AC current measuring accuracy: ±(1% + 2 digit)
DC voltage measuring accuracy: ±(0.1% + 1 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1.2% + 4 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x4
Interface: IrDA
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010; EN 61243-3:2010
Anzahl je Verpackung: 1 Stücke
Category: Calibrators
Description: Meter: multimeter calibrator; Diode test: 0.3mA@600mV
Related items: POM-5900A/POM; POM-6173A; POM-7519A
Dimensions: 203x100x50mm
Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads
Measuring instrument features: 0% or 100% of signal value (4mA, 20mA) source function; 24V loop supply voltage; automatic and manual setting of step function; HART range with loop and built-in 250Ω resistor; HOLD function; impact resistant holster; MIN/MAX/MEAN/REL function; simultaneous readout in mA and % of range; source DC current / calibrate loop current, source/simulate
Type of meter: multimeter calibrator
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; crocodile clip FLK-AC89; crocodile clip FLK-AC220; crocodile clip FLK-AC283; crocodile clip FLK-AC285; FLK-C510 - soft cover; FLK-FVF-SC2 software; FLK-TL225 set
Continuity test: acoustic indication; <100Ω
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; resistance
AC current measuring range: 0.001mA...1A
Resistance measuring range: 100mΩ...400Ω; 4kΩ; 400kΩ; 4MΩ; 40MΩ
DC current measuring range: 1µA...30mA; 1A
DC voltage measuring range: 1...400mV; 4V; 40V; 400V; 1kV
AC voltage measuring range: 0.1...400mV; 4V; 40V; 400V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.99kHz
Diode test: 0.3mA @600mV
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Software: Fluke Connect (FLK-IR3000FC)
Frequency measuring accuracy: ±(0.005%+1 digit)
AC current measuring accuracy: ±(1% + 2 digit)
DC voltage measuring accuracy: ±(0.1% + 1 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1.2% + 4 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x4
Interface: IrDA
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010; EN 61243-3:2010
Anzahl je Verpackung: 1 Stücke
auf Bestellung 2 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl | Preis ohne MwSt |
---|---|
1+ | 2154.47 EUR |
Produktrezensionen
Produktbewertung abgeben
Technische Details FLUKE 789 FLUKE
Category: Calibrators, Description: Meter: multimeter calibrator; Diode test: 0.3mA@600mV, Related items: POM-5900A/POM; POM-6173A; POM-7519A, Dimensions: 203x100x50mm, Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads, Measuring instrument features: 0% or 100% of signal value (4mA, 20mA) source function; 24V loop supply voltage; automatic and manual setting of step function; HART range with loop and built-in 250Ω resistor; HOLD function; impact resistant holster; MIN/MAX/MEAN/REL function; simultaneous readout in mA and % of range; source DC current / calibrate loop current, source/simulate, Type of meter: multimeter calibrator, Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; crocodile clip FLK-AC89; crocodile clip FLK-AC220; crocodile clip FLK-AC283; crocodile clip FLK-AC285; FLK-C510 - soft cover; FLK-FVF-SC2 software; FLK-TL225 set, Continuity test: acoustic indication; .
Weitere Produktangebote FLUKE 789 nach Preis ab 2154.47 EUR bis 2730.49 EUR
Foto | Bezeichnung | Hersteller | Beschreibung |
Verfügbarkeit |
Preis ohne MwSt | ||||
---|---|---|---|---|---|---|---|---|---|
+2 |
FLUKE 789 | Hersteller : FLUKE |
Category: Calibrators Description: Meter: multimeter calibrator; Diode test: 0.3mA@600mV Related items: POM-5900A/POM; POM-6173A; POM-7519A Dimensions: 203x100x50mm Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads Measuring instrument features: 0% or 100% of signal value (4mA, 20mA) source function; 24V loop supply voltage; automatic and manual setting of step function; HART range with loop and built-in 250Ω resistor; HOLD function; impact resistant holster; MIN/MAX/MEAN/REL function; simultaneous readout in mA and % of range; source DC current / calibrate loop current, source/simulate Type of meter: multimeter calibrator Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; crocodile clip FLK-AC89; crocodile clip FLK-AC220; crocodile clip FLK-AC283; crocodile clip FLK-AC285; FLK-C510 - soft cover; FLK-FVF-SC2 software; FLK-TL225 set Continuity test: acoustic indication; <100Ω Measurement: AC current; AC voltage; DC current; DC voltage; frequency; resistance AC current measuring range: 0.001mA...1A Resistance measuring range: 100mΩ...400Ω; 4kΩ; 400kΩ; 4MΩ; 40MΩ DC current measuring range: 1µA...30mA; 1A DC voltage measuring range: 1...400mV; 4V; 40V; 400V; 1kV AC voltage measuring range: 0.1...400mV; 4V; 40V; 400V; 1kV Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.99kHz Diode test: 0.3mA @600mV Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Software: Fluke Connect (FLK-IR3000FC) Frequency measuring accuracy: ±(0.005%+1 digit) AC current measuring accuracy: ±(1% + 2 digit) DC voltage measuring accuracy: ±(0.1% + 1 digit) DC current measuring accuracy: ±(0.2% + 2 digit) AC voltage measuring accuracy: ±(1.2% + 4 digit) Resistance measuring accuracy: ±(0.2%+1 digit) Kind of display used: LCD Power supply: battery LR6 AA 1,5V x4 Interface: IrDA Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010; EN 61243-3:2010 |
auf Bestellung 2 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||
FLUKE-789 | Hersteller : Fluke Electronics |
Description: PROCESSMETER DMM W/4-20MA SOURCE Features: Auto Off, Backlight, Hold, Min/Max/Ave Packaging: Box Display Type: LCD, Dual Style: Handheld Function: Voltage, Current, Resistance, Frequency Type: Digital (DMM) Ranging: Auto/Manual Ratings: CAT III 1000V, CAT IV 600V Display Count: 20000 Functions, Extra: Continuity, Diode Test Response: True RMS Part Status: Active Display Digits: 4.5 |
auf Bestellung 8 Stücke: Lieferzeit 10-14 Tag (e) |
|
|||||
FLUKE-789 | Hersteller : Fluke | Processmeter Safety-Designed Alkaline Batteries |
auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) |
|
|||||
FLUKE-789 | Hersteller : Fluke | Calibration Equipment PROCESSMETER |
Produkt ist nicht verfügbar |