![AX-176 AX-176](https://ce8dc832c.cloudimg.io/v7/_cdn_/98/B8/60/00/1/428937_1.jpg?width=640&height=480&wat=1&wat_url=_tme-wrk_%2Ftme_new.png&wat_scale=100p&ci_sign=de42363311cab95b77228b3f243dd4a3a8594161)
AX-176 AXIOMET
Hersteller: AXIOMET
Category: Portable digital multimeters
Description: Digital multimeter; USB; LCD; (6600); 3x/s; True RMS; Temp: 0÷40°C
Type of meter: digital multimeter
Interface: USB
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; resistance; temperature
Kind of display used: LCD
Display parameters: (6600)
Sampling: 3x/s
DC voltage measuring range: 0.1...660mV; 6.6V; 66V; 660V; 1kV
DC voltage measuring accuracy: ±(0.8% + 5 digit)
AC voltage measuring range: 0.1...660mV; 6.6V; 66V; 660V; 1kV
AC voltage measuring accuracy: ±(1% + 5 digit)
DC current measuring range: 0.1...660µA; 6.6mA; 66mA; 600mA; 10A
DC current measuring accuracy: ±(1.5% + 3 digit)
AC current measuring range: 0.1...660µA; 6.6mA; 66mA; 600mA; 10A
AC current measuring accuracy: ±(1.8% + 8 digit)
True effective value measurement: True RMS
Resistance measuring range: 100mΩ...660Ω; 6.6kΩ; 66kΩ; 660kΩ; 6.6MΩ; 66MΩ
Capacitance measuring range: 1pF...6.6nF; 66nF; 660nF; 6.6µF; 66µF; 660µF; 6.6mF; 66mF
Capacitance measuring accuracy: ±(3%+ 3 digit)
Frequency measuring range: 10mHz...66Hz; 660Hz; 6.6kHz; 66kHz; 660kHz; 6.6MHz; 66MHz
Frequency measuring accuracy: ±(0.1%+3 digit)
Temperature measuring range: -55...1000°C
Temperature measurement accuracy: ±(2% + 3°C)
Resistance measuring accuracy: ±(1.2%+2 digit)
Duty cycle factor: 1...99%
Duty cycle factor measurement accuracy: ±(2% + 10 digits)
Diode test: 1mA @2.8V
Continuity test: acoustic indication; <30Ω
Operating temperature: 0...40°C
Pollution degree: 2
Storage temperature: -10...60°C
Weight with battery: 500g
Power supply: battery 6F22 9V x1
Standard equipment: drop-like K-type temperature probe; test leads; USB cable
Optional equipment: test leads AX-TL-4B1-B; test leads AX-TL-4B1-BL; test leads AX-TL-4B1-R; test leads AX-TL-BNC-4BP2; test leads AX-TLP-001; test leads AX-TLP-001T; test leads AX-TLP-002; test leads AX-TLP-003; test leads AX-TLS-001B; test leads AX-TLS-002B; test leads AX-TLS-003A; test leads AX-TLS-004A; test leads AX-TLS-005A; test leads AX-TLS-007S; test leads PPOM-14; test tweezers AX-TLP-TW-01
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: 5790D; 5793D; 5794D; 5795D; 5797D; BKP60; EX871515; EX881602; EX881603; EX881605; PKT-PTA; PKT-PTF-10; PKT-PTF-20; PKT-PTF-25; PKT-PTF-30; PKT-PTF-40; PKT-PTF-50; PKT-PTF-55; PKT-PTF-56; PKT-PTF-60; SE027; SE028; SE029; SE030; SE031; SE059; SE060; SE061; SE062; SE001; SE002; SE003; SE004; SE000; TESTO-06020393; TESTO-06020645; TESTO-06024592; TESTO-06024892; TESTO-06280020; TESTO-06281292; TESTO-06287533; TP200; TP400; TP870; TP873; TP873-5M; TP882; TP-111; TP-112; TP-02; TP-03; TP-04; TP-06; TP-08; TP-09; TPK-59; TPK-62; UTT10K; UTT12
Kind of output connector: USB A plug
Dimensions (W x H x D): 90x190x40mm
Measuring instrument features: auto and manual ranging; automatic power-off; HOLD function; low battery indicator; MIN/MAX/REL function
Battery/ rechargeable battery: battery 6F22 9V x1
Software: included
Illumination: yes
Anzahl je Verpackung: 1 Stücke
Category: Portable digital multimeters
Description: Digital multimeter; USB; LCD; (6600); 3x/s; True RMS; Temp: 0÷40°C
Type of meter: digital multimeter
Interface: USB
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; resistance; temperature
Kind of display used: LCD
Display parameters: (6600)
Sampling: 3x/s
DC voltage measuring range: 0.1...660mV; 6.6V; 66V; 660V; 1kV
DC voltage measuring accuracy: ±(0.8% + 5 digit)
AC voltage measuring range: 0.1...660mV; 6.6V; 66V; 660V; 1kV
AC voltage measuring accuracy: ±(1% + 5 digit)
DC current measuring range: 0.1...660µA; 6.6mA; 66mA; 600mA; 10A
DC current measuring accuracy: ±(1.5% + 3 digit)
AC current measuring range: 0.1...660µA; 6.6mA; 66mA; 600mA; 10A
AC current measuring accuracy: ±(1.8% + 8 digit)
True effective value measurement: True RMS
Resistance measuring range: 100mΩ...660Ω; 6.6kΩ; 66kΩ; 660kΩ; 6.6MΩ; 66MΩ
Capacitance measuring range: 1pF...6.6nF; 66nF; 660nF; 6.6µF; 66µF; 660µF; 6.6mF; 66mF
Capacitance measuring accuracy: ±(3%+ 3 digit)
Frequency measuring range: 10mHz...66Hz; 660Hz; 6.6kHz; 66kHz; 660kHz; 6.6MHz; 66MHz
Frequency measuring accuracy: ±(0.1%+3 digit)
Temperature measuring range: -55...1000°C
Temperature measurement accuracy: ±(2% + 3°C)
Resistance measuring accuracy: ±(1.2%+2 digit)
Duty cycle factor: 1...99%
Duty cycle factor measurement accuracy: ±(2% + 10 digits)
Diode test: 1mA @2.8V
Continuity test: acoustic indication; <30Ω
Operating temperature: 0...40°C
Pollution degree: 2
Storage temperature: -10...60°C
Weight with battery: 500g
Power supply: battery 6F22 9V x1
Standard equipment: drop-like K-type temperature probe; test leads; USB cable
Optional equipment: test leads AX-TL-4B1-B; test leads AX-TL-4B1-BL; test leads AX-TL-4B1-R; test leads AX-TL-BNC-4BP2; test leads AX-TLP-001; test leads AX-TLP-001T; test leads AX-TLP-002; test leads AX-TLP-003; test leads AX-TLS-001B; test leads AX-TLS-002B; test leads AX-TLS-003A; test leads AX-TLS-004A; test leads AX-TLS-005A; test leads AX-TLS-007S; test leads PPOM-14; test tweezers AX-TLP-TW-01
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: 5790D; 5793D; 5794D; 5795D; 5797D; BKP60; EX871515; EX881602; EX881603; EX881605; PKT-PTA; PKT-PTF-10; PKT-PTF-20; PKT-PTF-25; PKT-PTF-30; PKT-PTF-40; PKT-PTF-50; PKT-PTF-55; PKT-PTF-56; PKT-PTF-60; SE027; SE028; SE029; SE030; SE031; SE059; SE060; SE061; SE062; SE001; SE002; SE003; SE004; SE000; TESTO-06020393; TESTO-06020645; TESTO-06024592; TESTO-06024892; TESTO-06280020; TESTO-06281292; TESTO-06287533; TP200; TP400; TP870; TP873; TP873-5M; TP882; TP-111; TP-112; TP-02; TP-03; TP-04; TP-06; TP-08; TP-09; TPK-59; TPK-62; UTT10K; UTT12
Kind of output connector: USB A plug
Dimensions (W x H x D): 90x190x40mm
Measuring instrument features: auto and manual ranging; automatic power-off; HOLD function; low battery indicator; MIN/MAX/REL function
Battery/ rechargeable battery: battery 6F22 9V x1
Software: included
Illumination: yes
Anzahl je Verpackung: 1 Stücke
auf Bestellung 19 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl | Preis ohne MwSt |
---|---|
1+ | 105.51 EUR |
Produktrezensionen
Produktbewertung abgeben
Technische Details AX-176 AXIOMET
Category: Portable digital multimeters, Description: Digital multimeter; USB; LCD; (6600); 3x/s; True RMS; Temp: 0÷40°C, Type of meter: digital multimeter, Interface: USB, Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; resistance; temperature, Kind of display used: LCD, Display parameters: (6600), Sampling: 3x/s, DC voltage measuring range: 0.1...660mV; 6.6V; 66V; 660V; 1kV, DC voltage measuring accuracy: ±(0.8% + 5 digit), AC voltage measuring range: 0.1...660mV; 6.6V; 66V; 660V; 1kV, AC voltage measuring accuracy: ±(1% + 5 digit), DC current measuring range: 0.1...660µA; 6.6mA; 66mA; 600mA; 10A, DC current measuring accuracy: ±(1.5% + 3 digit), AC current measuring range: 0.1...660µA; 6.6mA; 66mA; 600mA; 10A, AC current measuring accuracy: ±(1.8% + 8 digit), True effective value measurement: True RMS, Resistance measuring range: 100mΩ...660Ω; 6.6kΩ; 66kΩ; 660kΩ; 6.6MΩ; 66MΩ, Capacitance measuring range: 1pF...6.6nF; 66nF; 660nF; 6.6µF; 66µF; 660µF; 6.6mF; 66mF, Capacitance measuring accuracy: ±(3%+ 3 digit), Frequency measuring range: 10mHz...66Hz; 660Hz; 6.6kHz; 66kHz; 660kHz; 6.6MHz; 66MHz, Frequency measuring accuracy: ±(0.1%+3 digit), Temperature measuring range: -55...1000°C, Temperature measurement accuracy: ±(2% + 3°C), Resistance measuring accuracy: ±(1.2%+2 digit), Duty cycle factor: 1...99%, Duty cycle factor measurement accuracy: ±(2% + 10 digits), Diode test: 1mA @2.8V, Continuity test: acoustic indication; .
Weitere Produktangebote AX-176 nach Preis ab 105.51 EUR bis 105.51 EUR
Foto | Bezeichnung | Hersteller | Beschreibung |
Verfügbarkeit |
Preis ohne MwSt | ||||
---|---|---|---|---|---|---|---|---|---|
![]() +7 |
AX-176 | Hersteller : AXIOMET |
Category: Portable digital multimeters Description: Digital multimeter; USB; LCD; (6600); 3x/s; True RMS; Temp: 0÷40°C Type of meter: digital multimeter Interface: USB Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; resistance; temperature Kind of display used: LCD Display parameters: (6600) Sampling: 3x/s DC voltage measuring range: 0.1...660mV; 6.6V; 66V; 660V; 1kV DC voltage measuring accuracy: ±(0.8% + 5 digit) AC voltage measuring range: 0.1...660mV; 6.6V; 66V; 660V; 1kV AC voltage measuring accuracy: ±(1% + 5 digit) DC current measuring range: 0.1...660µA; 6.6mA; 66mA; 600mA; 10A DC current measuring accuracy: ±(1.5% + 3 digit) AC current measuring range: 0.1...660µA; 6.6mA; 66mA; 600mA; 10A AC current measuring accuracy: ±(1.8% + 8 digit) True effective value measurement: True RMS Resistance measuring range: 100mΩ...660Ω; 6.6kΩ; 66kΩ; 660kΩ; 6.6MΩ; 66MΩ Capacitance measuring range: 1pF...6.6nF; 66nF; 660nF; 6.6µF; 66µF; 660µF; 6.6mF; 66mF Capacitance measuring accuracy: ±(3%+ 3 digit) Frequency measuring range: 10mHz...66Hz; 660Hz; 6.6kHz; 66kHz; 660kHz; 6.6MHz; 66MHz Frequency measuring accuracy: ±(0.1%+3 digit) Temperature measuring range: -55...1000°C Temperature measurement accuracy: ±(2% + 3°C) Resistance measuring accuracy: ±(1.2%+2 digit) Duty cycle factor: 1...99% Duty cycle factor measurement accuracy: ±(2% + 10 digits) Diode test: 1mA @2.8V Continuity test: acoustic indication; <30Ω Operating temperature: 0...40°C Pollution degree: 2 Storage temperature: -10...60°C Weight with battery: 500g Power supply: battery 6F22 9V x1 Standard equipment: drop-like K-type temperature probe; test leads; USB cable Optional equipment: test leads AX-TL-4B1-B; test leads AX-TL-4B1-BL; test leads AX-TL-4B1-R; test leads AX-TL-BNC-4BP2; test leads AX-TLP-001; test leads AX-TLP-001T; test leads AX-TLP-002; test leads AX-TLP-003; test leads AX-TLS-001B; test leads AX-TLS-002B; test leads AX-TLS-003A; test leads AX-TLS-004A; test leads AX-TLS-005A; test leads AX-TLS-007S; test leads PPOM-14; test tweezers AX-TLP-TW-01 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Related items: 5790D; 5793D; 5794D; 5795D; 5797D; BKP60; EX871515; EX881602; EX881603; EX881605; PKT-PTA; PKT-PTF-10; PKT-PTF-20; PKT-PTF-25; PKT-PTF-30; PKT-PTF-40; PKT-PTF-50; PKT-PTF-55; PKT-PTF-56; PKT-PTF-60; SE027; SE028; SE029; SE030; SE031; SE059; SE060; SE061; SE062; SE001; SE002; SE003; SE004; SE000; TESTO-06020393; TESTO-06020645; TESTO-06024592; TESTO-06024892; TESTO-06280020; TESTO-06281292; TESTO-06287533; TP200; TP400; TP870; TP873; TP873-5M; TP882; TP-111; TP-112; TP-02; TP-03; TP-04; TP-06; TP-08; TP-09; TPK-59; TPK-62; UTT10K; UTT12 Kind of output connector: USB A plug Dimensions (W x H x D): 90x190x40mm Measuring instrument features: auto and manual ranging; automatic power-off; HOLD function; low battery indicator; MIN/MAX/REL function Battery/ rechargeable battery: battery 6F22 9V x1 Software: included Illumination: yes |
auf Bestellung 19 Stücke: Lieferzeit 14-21 Tag (e) |
|